作者机构:Sarulla Operations Ltd. 7th Floor the Energy Building SCBD Lot 11A Jakarta 12190 Indonesia Geothermal Engineering Master's Program Faculty of Mining and Petroleum Engineering Institut Teknologi Bandung Jl. Ganesha 10 Bandung 40132 Indonesia
出 版 物:《IOP Conference Series: Earth and Environmental Science》
年 卷 期:2021年第732卷第1期
摘 要:The Silangkitang (SIL) geothermal system is a fault-controlled and liquid-dominated reservoir associated to a deep heat source. Geology data from recent development drilling and reservoir monitoring demonstrated that the high permeability is concentrated within zone between two strands of Great Sumatra Fault (GSF). These faults are major dextral strike slip system that cross the entire length of Sumatra Island. The fault distribution has been defined by integration and interpretation of tectonic geomorphology, surface geology, and well geology. The highest permeability is controlled by faults and fractures associated with localized releasing steps within west of main Tor Sibohi Fault (TSF). This paper outlines the indication of high permeability zone based on recent geology evaluation outcome.