咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Inertia Response Coordination ... 收藏

Inertia Response Coordination Strategy of Wind Generators and Hybrid Energy Storage and Operation Cost-Based Multi-Objective Optimizing of Frequency Control Parameters

作     者:Rahimi, Tohid Ding, Lei Kheshti, Mostafa Faraji, Rasoul Guerrero, Josep M. Tinajero, Gibran David Agundis 

作者机构:Shandong Univ Sch Elect Engn Key Lab Power Syst Intelligent Dispatch & Control Minist Educ Jinan 250061 Peoples R China Aalborg Univ Dept Energy Technol DK-9220 Aalborg Denmark 

出 版 物:《IEEE ACCESS》 (IEEE Access)

年 卷 期:2021年第9卷

页      面:74684-74702页

核心收录:

基  金:China Postdoctoral Science Foundation [2019M662357, 2019M662356] National Natural Science Foundation of China Innovation Project of Shandong Province Project of Shandong Province New and Old Kinetic Energy Conversion VILLUM FONDEN, Center for Research on Microgrids (CROM) 

主  题:Frequency control Wind turbines Generators Wind speed Renewable energy sources Energy storage Batteries Microgrid (MG) frequency control wind generator hybrid energy storage (HES) ultra-capacitor inertia response multi-objective optimization 

摘      要:Due to the high penetration of renewable energy resources in microgrids (MGs), the grid inertia becomes low which leads to the grid to be vulnerable to large disturbances. The energy storage devices can play an important role to enhance the inertia of MGs. However, due to the high investment cost of storages or their dp/dt limitation, the installed energy storages cannot cover the challenge of high df/dt. A prominent solution to solve the problem is to use the inertia response of the wind generators. However, relatively high second frequency nadir is the main drawback of using the inertia response of the wind generators which may impose an extensive disturbance to MGs. Accordingly, a coordinated operation strategy for MGs between wind generator and hybrid energy storage (HES) system is proposed in this paper. In addition, to improve the inertia response of the MG;providing high-quality communication infrastructures with low delay and increasing the Ultracapacitor capacity have been paid attention. In this paper, the costs of the installed Ultracapacitor and quality of communication services are defined as the operation cost. Guaranteeing enough frequency damping for the MG with low operation cost are two conflict objectives. Therefore, a multi-objective optimization method is used to set the controllers values and reduce the operation cost. The results confirmed that the effectiveness of the proposed strategy to control hybrid power storage in coordination with the wind generator and the frequency recovery process is improved. Also, employing the optimum values guaranteed the frequency damping effectively with low operation cost. The Integral Absolute Error (IAE) value and operation cost are reduced by 13.6% and 32%, respectively. Also, the simulation results show that the maximum MG frequency deviation and maximum df/dt is well compatible with different standards in the presence of load perturbations and different wind speeds.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分