版权所有:内蒙古大学图书馆 技术提供:维普资讯• 智图
内蒙古自治区呼和浩特市赛罕区大学西街235号 邮编: 010021
作者机构:Tongji Univ Dept Geotech Engn Shanghai 200092 Peoples R China Univ Politecn Catalunya UPC Dept Civil & Environm Engn Barcelona 08034 Spain Xinjiang Univ Coll Civil Engn & Architecture Urumqi 830047 Peoples R China Tongji Univ Minist Educ State Key Lab Geotech & Underground Engn Shanghai 200092 Peoples R China Uppsala Univ Dept Earth Sci SE-75236 Uppsala Sweden
出 版 物:《TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY》 (Tunn. Undergr. Space Technol.)
年 卷 期:2025年第158卷
核心收录:
学科分类:08[工学] 0813[工学-建筑学] 0814[工学-土木工程]
基 金:National Natural Science Foundation of China Fundamental Research Funds for the Central Universities China Scholarship Council
主 题:Shield tunnel Gasketed joint Sealant performance A -star algorithm Leakage path Localized leakage
摘 要:Joint leakage is one of the major problems for shield tunnels. This paper proposes a novel approach to assessing the sealant performance of gasketed joints based on the A-star search algorithm. By treating the contact surface of gaskets as the search space of the optimal leakage path, the water leakage process is modeled as a path optimization task informed by the nonuniform distribution of contact stresses. This new approach determines the optimal leakage path together with the associated leakage threshold. The validity of the proposed algorithm is demonstrated through a comparison with experimental test results, followed by a comprehensive parametric study of joint opening, offset, and self-sealing effect. The results elucidate the dominant role of localized contact in sealant performance, which is notably affected by joint deformation. Scenarios of large offsets and small openings exhibit abnormal increases in leakage thresholds and elongated leakage paths due to additional gasketto-groove contacts and increased heterogeneity of contact stress distribution. The self-sealing process exerts a pronounced nonlinear impact on the sealant performance of gasketed joints, leading to a rapid escalation of the leakage threshold when the lateral water pressure surpasses 0.5 MPa. Additionally, lateral pressurization induces nonuniform distribution of non-conductive regions, resulting in convoluted optimal leakage paths.