咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Analysis of Variable Frequency... 收藏

Analysis of Variable Frequency Energy-Saving Operation of Beam Pumping Unit

作     者:Jinping He Kai Ji Ming Xu Guozhu Mei Derong Lin Huanjing Xia 

作者机构:National Key Laboratory of Science and Technology on Vessel Integrated Power System Wuhan Institute of Marine Electric Propulsion Wuhan China 

出 版 物:《IOP Conference Series: Materials Science and Engineering》 

年 卷 期:2018年第452卷第4期

摘      要:The frequency converter has been applied in the beam pumping unit, but the field application is still immature, and the energy saving effect is not ideal. This paper briefly analyzes the movement law of the beam pumping unit, and makes a proper simplification of the suspension point load. It derives the work done by the motor in one stroke of the steam head, and combines the oil recovery per unit time of the pumping unit. The operating law of the inverter when the ratio of motor energy consumption to oil production is the smallest. Finally, through simulation analysis, it is verified that the energy consumption of the slow and fast operation mode is lower than that of the constant speed operation mode.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分