文献详情 >Modelling and Optimization of ... 收藏

Modelling and Optimization of the Direct Air Cooling Power Generation Unit

作     者:Zhu, Mingjuan Shen, Jiong Lee, Kwang Y. Wu, Xiao 

作者机构:Key Lab of Energy Thermal Conversion and Control of Ministry of Education Southeast University Nanjing China Department of Electrical and Computer Engineering Baylor University WacoTX76798 United States 

出 版 物:《IFAC-PapersOnLine》 

年 卷 期:2018年第51卷第28期

页      面:696-701页

核心收录:

基  金:This work was supported by the National Natural Science Foundation of China (NSFC) under Grant 51576041  the Natural Science Foundation of Jiangsu Province under Grant BK20141119  and China Scholarship Council 

主  题:Cooling Atmospheric temperature Condensation Electric power generation Fossil fuel power plants Fossil fuels Meteorology Steam Water conservation Air cooling condenser Condensation pressure Cost of electricity Economic operations Energy structures Online optimization Power production Reference values 

摘      要:Fossil fuel power plants dominate the energy structure in China. However, the water scarcity, in Southeast/Southwest China, results in the development of the dry cooling power plants. Direct air cooling condenser (DACC) is appealing for its water saving ability. In DACC, the exhaust steam is cooled and condensed to water by the air flow, which is provided by the fan array at the cost of electricity. There exists a varying optimal exhaust steam pressure under different air temperatures and loads. The static model of the turbine-DACC system is built to quantify the influences of the air temperatures and loads. An on-line optimization is used here to set the reference value of the exhaust steam pressure for the turbine-DACC system for economic operation. The objective is to maximize the net power production while satisfying the constraints on the safety pressure and the available air flowrate. The optimization is conducted in a model 660MW power plant selected on a random summer/winter day. The hourly optimal exhaust steam pressure and the operation instructions are calculated as the reference values for the control layer. The optimization results show that the optimal exhaust steam pressure may be too close to the safety limits in winter, suggesting the safety also to be considered in the optimization. In summer, the DACC system cannot satisfy the condensation load sometimes. Thus, a complementary cooling method, for example, the wet cooling, is needed to reduce the burden on the DACC system. © 2018