咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Fault-Decoupled Instantaneous ... 收藏

Fault-Decoupled Instantaneous Frequency and Phase Angle Estimation for Three-Phase Grid-Connected Inverters

作     者:De Donato, G. Scelba, G. Borocci, G. Capponi, F. Giulii Scarcella, G. 

作者机构:Univ Roma La Sapienza Dept Astronaut Elect & Energet Engn I-00184 Rome Italy Univ Catania Dept Elect Elect & Comp Engn I-95127 Catania Italy 

出 版 物:《IEEE TRANSACTIONS ON POWER ELECTRONICS》 (IEEE Trans Power Electron)

年 卷 期:2016年第31卷第4期

页      面:2880-2889页

核心收录:

学科分类:0808[工学-电气工程] 08[工学] 

主  题:Estimation algorithm fault ride through frequency grid connection harmonics phase angle phase-locked loop (PLL) 

摘      要:Frequency and phase angle estimation is a key aspect for grid-connected inverters that are required to guarantee low-voltage fault-ride-through capability. Over the past two decades, a number of estimation algorithms have been proposed, mostly based on the well-known phase-locked loop (PLL). It has been demonstrated that standard PLLs do not perform correctly in abnormal grid conditions, due to the oscillations produced in the frequency and phase angle estimates by the voltage harmonics. This paper introduces a new, general approach to harmonic decoupling and presents a highly intuitive and simple scheme, applying it to an alpha beta-PLL;compensation of any desired number of harmonic components is possible. Two implementations of this decoupling scheme are presented. It is shown that the performances of the resulting fault-decoupled PLLs are comparable with those of other advanced frequency and phase angle estimation structures.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分