咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Frontier analysis on optimal i... 收藏

Frontier analysis on optimal inspection times for reinforced concrete structures

作     者:Pablo Benítez Eugénio Rocha Fernanda Rodrigues 

作者机构:1RISCO Department of Civil Engineering University of Aveiro Portugal 2Center for Research and Development in Mathematics and Applications Department of Mathematics University of Aveiro Portugal 

出 版 物:《AIP Conference Proceedings》 

年 卷 期:2019年第2116卷第1期

学科分类:07[理学] 0702[理学-物理学] 

摘      要:Reinforced concrete is one of the most predominant materials in infrastructures throughout the world, hence management of the structures maintenance is an important subject of study in order to slow down the degradation process and to extend a structure lifespan. This work focus on a numerical model to find the best inspection planning for concrete structures under carbonation- induced corrosion, decomposed in three steps: (a) estimate the probability density function for critical failure time, (b) determine the optimal times for inspections sequences maximising its detectability; (c) multi-objective optimisation via frontier analysis to have a final relative ranking of inspection sequences. In short, this work answer the questions: when the inspections should be done and what are the best inspections for a given efficiency metric, under a set of parameters characterising the degradation process and inspection capabilities. Our formulation extend the models in the literature (e.g. detectability function) and its seems that the multidirectional efficiency analysis algorithm used here is better suited for real situations.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分