Aiming at the current problem of lack of effective data and high service latency for intrusion detection in smart substations, this paper proposes a lightweight intrusion detection method for smart substations. Throug...
详细信息
This research focus on the position tracking control of the barrel pitching electro-hydraulic servo system with model uncertainties. Based on the established dynamic model of the sytem, a disturbance observer-based in...
详细信息
This study uses JAYA optimized model predictive control to address a three-area load frequency regulation problem that actively involves stochastic renewable energy sources. Some physical constraints employed in the s...
详细信息
This study uses JAYA optimized model predictive control to address a three-area load frequency regulation problem that actively involves stochastic renewable energy sources. Some physical constraints employed in the system model, such as the generation rate constraint, dead band, and time delay by governor-turbine, negatively impact the control performance of the classical MPC technique. As such, a more robust control scheme is required to get rid of this flaw. The JAYA algorithm is adopted to dynamically tune the parameters of MPC, which is a parameter-driven controller for optimal system performance. The performance indices such as the integral of square error (ISE), integral of time multiplied by square error (ITSE), integral of the absolute value of error (IAE), and integral of time multiplied by the absolute value of error (ITAE) have been used to compare the effectiveness of the proposed controller with the classical MPC with constant tuning parameters. The suggested controller is superior to the conventional MPC, as demonstrated by the results from the MATLAB/Simulink environment. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://***/licenses/by-nc-nd/4.0/).
This paper presents the control Technique for a bi-directional AC-DC interlinking Converter and a fault protection scheme for an AC-DC Hybrid Microgrid. In this paper, an IEEE 7 bus ring main system-based AC-DC hybrid...
详细信息
The operation data of the predictive control system is nonlinear, sequential and dynamic. The implicit nonlinear transformation of the traditional support vector data description (SVDD) cannot represent the timing and...
详细信息
Multi-machine parallel operation of medium-voltage power generation vehicles can meet more load demand, which is an important development direction of mobile power generation vehicles. However, simple parallel connect...
详细信息
Due to the presence of nonlinear power devices in rectifiers, a large amount of harmonic pollution will be generated during system operation. Harmonic pollution has a significant impact on the stability and efficiency...
详细信息
To meet the requirements for flexible control of power electronic equipment connected to the power network, this article compares topology results of the intelligent flexible switch, establishes the equivalent model o...
详细信息
In the high voltage power supply of the negative ion source neutral beam injection system (NNBI) accelerator, the three-phase three-level neutral point clamping (NPC) inverter, as an inverter module, has a detectable ...
详细信息
In the high voltage power supply of the negative ion source neutral beam injection system (NNBI) accelerator, the three-phase three-level neutral point clamping (NPC) inverter, as an inverter module, has a detectable DC component in its output. When it flows into the step-up transformer, it will lead to increased transformer loss and excitation saturation, thus reducing the service life of the transformer and increasing potential safety hazards. This paper analyzes the causes of the DC component of the NPC inverter, and a reliable DC component suppression method based on double-loop control is proposed. A suitable PI controller can effectively suppress the output DC component during the power supply operation by establishing the transfer function between the output DC component and the regulation rate of the switch's duty cycle. Finally, the prototype experiments verify the effectiveness of the control method successfully. (C) 2023 Published by Elsevier Ltd. This is an open access article under theCCBY-NC-ND license (http://***/licenses/by-nc-nd/4.0/).
This research presents an eleven-level multilevel inverter with decreased switching count and voltage stress. There are only 7 switches in the architecture, including 1 bidirectional switch and 2 capacitors. The inver...
详细信息
暂无评论