A new detector for PET using multi-pixel photon counters (MPPCs) was developed for MRI compatible applications. This module has an 8 × 8 MPPC array, each segment has a 3 mm × 3 mm active area, and the pitch ...
详细信息
A new detector for PET using multi-pixel photon counters (MPPCs) was developed for MRI compatible applications. This module has an 8 × 8 MPPC array, each segment has a 3 mm × 3 mm active area, and the pitch of the array is 4.1 mm in both directions. A temperature sensor is attached to the back of the array for temperature compensation. The MPPC array is connected to the front-end circuit with a detachable flexible printed circuit cable (FPC), which provides flexibility for detector arrangement. The front-end circuit consists of preamplifiers, a register network, buffer amplifiers, a built-in high voltage (HV) unit, and an embedded microprocessor unit. The HV unit is a down-regulator and requires an external HV supply. The preamplifier also has a sum output, which can be used for timing pick-off and energy discrimination. With LYSOs, the timing performance was evaluated using flexible printed cables of two different lengths. Set in a copper shield box, energy spectra and flood images were evaluated with a 3T-MRI Very little interference was observed during simultaneous MRI measurements.
Silicon pressure sensors based on micro-electro-mechanical-systems (MEMS) technologies are gaining popularity for applications in bio-medical devices. In this study, a silicon piezo-resistive pressure sensor die is us...
This paper describes the fabrication of microelectrode arrays, with two different geometries: disc (Designs d1 and d2) and band (Designs b1, b2 and b3) using three critical dimensions (100 nm, 1 μm and 10 μm) leadin...
This paper describes the fabrication of microelectrode arrays, with two different geometries: disc (Designs d1 and d2) and band (Designs b1, b2 and b3) using three critical dimensions (100 nm, 1 μm and 10 μm) leading to 5 different designs, fabricated by the combination of UV photolithographic and e-beam lithographic techniques. Three silicon nitride layer thicknesses (200, 300 and 500 nm) were chosen to determine an optimized transducer design and fabrication process. Cyclic voltammetry characterisation using a simple redox probe ion, ferreocenecarboxylic acid in phosphate buffered saline electrolyte solution, demonstrated steady-state voltammetric curves for d1, d2, b1 and b2. A good agreement between experimental and theoretical data is found for devices d1, d2, b1 and b2. The experimental current for b3, on the other hand, is much lower compared to the calculated one- perhaps due to the overlapping of the diffusion layers of neighbouring microelectrodes in the array.