This paper presents a 6-8GHz 2Mb/s Chirp-UWB (C-UWB) transceiver implemented in 65nm CMOS. The transceiver performs burst-mode transmission with an optimum duty-cycle control by utilizing a steep digital gradient gene...
详细信息
This paper presents a 6-8GHz 2Mb/s Chirp-UWB (C-UWB) transceiver implemented in 65nm CMOS. The transceiver performs burst-mode transmission with an optimum duty-cycle control by utilizing a steep digital gradient generation circuit in the transmitter. To enhance sensitivity and interference immunity, a slope detection based decision method is employed in the receiver by utilizing a 2-bit continuous-time sample-and-hold ADC, which obtains more information of the received signal compared to the single-threshold decision. The 2Mb/s transceiver consumes 1.8mW from a 1V supply, achieving an energy efficiency of 0.9nJ/bit.
This paper presents a low power multi-channel chirp-UWB (C-UWB) transmitter for short range communication systems. The C-UWB transmitter generates a wideband FM signal with a steep spectral roll-off, while enabling a ...
详细信息
ISBN:
(纸本)9781509006977
This paper presents a low power multi-channel chirp-UWB (C-UWB) transmitter for short range communication systems. The C-UWB transmitter generates a wideband FM signal with a steep spectral roll-off, while enabling a duty-cycled operation. To achieve an optimum duty-cycle control, burst-mode transmission and steep digital gradient generation techniques are employed. A 5-to-9GHz C-UWB transmitter is implemented in 65nm CMOS for multi-channel operation with a channel bandwidth of 500MHz. The transmitter achieves 1Mb/s data rate, consuming 0.5mW from a 1V supply.
The measurement of volume pulse waves may be easily affected based on the measured position (different fingers or toes), body posture, as well as other factors. Therefore, interferences during measurement need to be r...
详细信息
The measurement of volume pulse waves may be easily affected based on the measured position (different fingers or toes), body posture, as well as other factors. Therefore, interferences during measurement need to be removed. For this study, relevant parameters of volume pulse wave were obtained by changing the affecting factors. The data were analyzed in order to indicate the differences in volume pulse wave parameters among different fingers and toes in four postures. Results showed that when subjects were lying, inclined or in a sitting posture, volume pulse wave parameters of the index finger, middle finger and ring finger on both hands displayed no apparent differences. When subjects were in a sitting posture, volume pulse wave parameters of the big, second and third toes on both feet showed no significant differences.
In allusion to the widespread anomalous data in substation primary equipment condition monitoring, this paper proposes an OPTICS (Ordering Points To Identify the Clustering Structure) clustering-based condition monito...
详细信息
BACKGROUND: Gestational diabetes mellitus (GDM) is not easily detected. The difficulty in detecting GDM is largely due to the late onset of clinical symptoms as well as the various complications that result from GDM [...
详细信息
BACKGROUND: Gestational diabetes mellitus (GDM) is not easily detected. The difficulty in detecting GDM is largely due to the late onset of clinical symptoms as well as the various complications that result from GDM [1]. OBJECTIVE: GDM greatly influences both mother and child. Therefore, the purpose of this study was to reduce the morbidity of GDM. METHODS: In this study, risk factors that influence GDM were selected through statistical analysis. Multivariable logistic regression analysis was used to obtain the regression equation and Odds Ratio (OR) value. The risk score of each factor was obtained according to the OR value. RESULTS: The score of every pregnant woman could be very intuitively used to show the risk of getting GDM. CONCLUSION: Through the above methods, a comprehensive risk evaluation method of detecting GDM was developed.
暂无评论