As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%;in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.
This paper describes our custom-designed wireless gait analysis sensor (WGAS) system developed and tested for real-time fall detection. The WGAS is capable of differentiating falls vs. Activities of Daily Living (ADL)...
详细信息
ISBN:
(纸本)9781467363624
This paper describes our custom-designed wireless gait analysis sensor (WGAS) system developed and tested for real-time fall detection. The WGAS is capable of differentiating falls vs. Activities of Daily Living (ADL) and the Dynamic Gait Index (DGI) performed by young volunteers using a backpropagationartificialneuralnetwork (BP ANN) algorithm. The WGAS, which includes a tri-axial accelerometer, 2 gyroscopes, and a MSP430 microcontroller is worn by the subjects at either T4 (at back) or the belt-clip positions (in front of the waist) for the various falls, ADL, and Dynamic Gait Index (DGI) tests. The raw data is wirelessly transmitted from the WGAS to a nearby PC for real-time fall classification, where six features were extracted for the BP ANN. Overall fall classification accuracies of 97.0% and 97.4% have been achieved for the data taken at the T4 and at the belt position, respectively. The preliminary data demonstrates an overall sensitivity of 97.0% and overall specificity of 97.2% for this WGAS fall detection system, showing good promise as a real-time low-cost and effective fall detection device for wireless acute care and wireless assisted living.
暂无评论