The American Standard method for determining the photographic speed of negative materials, and the corresponding British Standard, specify the 0.3 G ¯ fractional-gradient criterion for measuring speed sensitomet...
详细信息
The American Standard method for determining the photographic speed of negative materials, and the corresponding British Standard, specify the 0.3 G ¯ fractional-gradient criterion for measuring speed sensitometrically. This criterion was adopted because it gives speed values which correlate more closely with speeds obtained by picture tests than do the speeds obtained by any other known sensitometric speed criterion. A frequent criticism, however, of the 0.3 G ¯ criterion is that it is more difficult to operate and more subject to random errors than simpler criteria, such as the one based on a density of 0.1 above fog. In the present paper, two methods of evaluating speed are described which are simple to operate and which give highly repeatable results that agree closely with accurately measured 0.3 G ¯ speeds and with speeds based on picture tests. The first method utilizes a mathematical representation of a portion of the sensitometric curve and converts inertia speed to an approximation of 0.3 G ¯ speed by means of a measurement of the length of the toe of the curve. The second method converts the speed based on a density of 0.1 above fog to an approximation of 0.3 G ¯ speed by means of the density resulting from an exposure equal to twenty times that required for the density of 0.1 above fog. Both methods are suitable for practical use, but the first method is of particular interest in the mathematical theory of the shape of the sensitometric curve and its relation to speed. The second method is especially suited to rapid, routine determination of speeds and is adaptable to automatic computation of speeds from density measurements without the necessity of drawing the sensitometric curve.
A method is presented that can be used to measure the optical properties of opaque liquids. The absolute values of the reflectivities of the material under investigation are measured at near normal incidence and at an...
详细信息
A method is presented that can be used to measure the optical properties of opaque liquids. The absolute values of the reflectivities of the material under investigation are measured at near normal incidence and at an angle of 45°.
The design and construction of an ultraviolet bandpass filter of the design: dielectric stack, aluminum film, dielectric stack, is described. A maximum transmittance of 0.55 at 2650 Å and a full width at 0.5 T ma...
详细信息
The design and construction of an ultraviolet bandpass filter of the design: dielectric stack, aluminum film, dielectric stack, is described. A maximum transmittance of 0.55 at 2650 Å and a full width at 0.5 T max of 65 Å is attained.
暂无评论