As an important equipment in substations, 110kV current transformers play a role in measurement, control, and protection. Insulation defects are prone to occur during operation, and preventive tests should be conducte...
详细信息
Most existing nuclear radiation measurement circuits are implemented based on PCB board-level technology, which has low integration, significant signal loss, and is susceptible to environmental interference, thus prev...
详细信息
In this study, the mechanisms of the anode phenomena and anode erosion with various contact materials were investigated. Arc parameters were calculated, and the anode temperature was predicted with a transient self-co...
详细信息
In this study, the mechanisms of the anode phenomena and anode erosion with various contact materials were investigated. Arc parameters were calculated, and the anode temperature was predicted with a transient self-consistent model. The simulation results predicted a constricted arc column and obvious anode phenomena in Cu–Cr alloy contacts than in W–Cu alloy *** observation could be the reason for the concentrated anode erosion in Cu–Cr alloys. For the contacts made by pure tungsten(W) and W–Cu alloy, the anode temperature increased rapidly because of the low specific heat of W. However, the maximum energy flux from the arc column to the anode surface was lower than in other cases. The simulation results were compared with experimental results.
As an important part of power transmission, the safe operation of high-voltage cables is crucial. Partial discharge of 110 kV cable during operation is one of the main causes of cable failure, and it is of far-reachin...
详细信息
With increasing global concerns about clean energy in smart grids,the detection of power quality disturbances(PQDs)caused by energy instability is becoming more and more *** is well acknowledged that the PQD effects o...
详细信息
With increasing global concerns about clean energy in smart grids,the detection of power quality disturbances(PQDs)caused by energy instability is becoming more and more *** is well acknowledged that the PQD effects on power grid equipment are destructive and hazardous,which causes irreversible damage to underlying electrical/electronic equipment of the concerned intelligent *** order to ensure safe and reliable equipment implementation,appropriate PQDdetection technologiesmust be adopted to avoid such adverse *** paper summarizes the newly proposed and traditional PQD detection techniques in order to give a quick start to new researchers in the related field,where specific scenarios and events for which each technique is applicable are also clearly ***,comments on the future evolution of PQD detection techniques are *** the published review articles,this paper focuses on the new techniques from the last five years while providing a brief recap on traditional PQD detection techniques so as to supply researchers with a systematic and state-of-the-art review for PQD detection.
Adverse environmental conditions such as haze, rain, and dust can significantly impair visibility for vehicles in motion, leading to blurred vision. Traditional de-fogging techniques often encounter limitations, inclu...
详细信息
To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was ***...
详细信息
To address the challenge of achieving both high sensitivity and a high quality factor in quartz crystal microbalance(QCM)humidity sensors,a nanodiamond(ND)/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was *** material characteristics of ND,Ti_(3)C_(2)MXene,and ND/Ti_(3)C_(2)MXene composite were analyzed by transmission electron microscopy(TEM)and Fourier transform infrared(FTIR)*** experimental results demonstrated that the hydrophilic ND nanoparticles coated on Ti_(3)C_(2) MXene nanosheet prevented the self-stacking of Ti_(3)C_(2)MXene and enhanced the sensitivity of Ti_(3)C_(2) MXene-based QCM humidity ***,the high mechanical modulus of Ti_(3)C_(2) MXene material helped ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor to achieve a high quality factor(>20,000).ND/Ti_(3)C_(2)MXene compositecoated QCM humidity sensor exhibited a sensitivity of 82.45 Hz/%RH,a humidity hysteresis of 1.1%RH,fast response/recovery times,acceptable repeatability,and good stability from 11.3%RH to 97.3%*** response mechanism of ND/Ti_(3)C_(2) MXene composite-coated QCM humidity sensor was analyzed in combination with a bi-exponential kinetic adsorption ***,the potential application of ND/Ti_(3)C_(2)MXene composite-coated QCM humidity sensor was demonstrated through its frequency response to wooden blocks with different moisture contents.
We have implementation a wristwatch that utilizes a Silicon Photomultiplier (SiPM) and a CsI(Tl) crystal for radiation dose rate detection. Compared to traditional personal dosimeters, it offers advantages such as hig...
详细信息
Biological evolution has deepened our understanding of nature. Since the advent of civilization, humans have continually explored ways to record what they see and hear, from cave sketches to camera photography, with c...
详细信息
High power microwave early irradiation has a great potential in assisting excavators in breaking hard and abrasive rocks, radiation efficiency is a very important issue. The paper studied the radiation of standard rec...
详细信息
暂无评论