The design to meet consumer demand for safe, durable, attractive appearance and easy to use of socket, is an improvement and innovation in appearance and structure of the multi-jacks socket from anti-electric shock, m...
详细信息
Thallium-doped cesium iodide (CsI(Tl)) screens are widely used in X-ray imaging devices because of the columnar structure of the CsI(Tl) layer,but few reports focus on the optical role of the substrate in the screen *...
详细信息
Thallium-doped cesium iodide (CsI(Tl)) screens are widely used in X-ray imaging devices because of the columnar structure of the CsI(Tl) layer,but few reports focus on the optical role of the substrate in the screen *** this paper,four substrates including fused silica (SiO2),silver-film coated SiO2,graphite (C) and fiber optic plate (FOP) are used to fabricate CsI(Tl) screens by thermal *** imaging performance is evaluated by relative light output (RLO),modulation transfer function (MTF),normalized noise power spectrum (NNPS) and noise equivalent quanta (NEQ).The results reveal that although CsI(Tl) film on graphite plate yields images with the lowest light output,it presents relatively higher spatial resolution and better signal-to-noise ***,films on SiO2 plate obtain low MTF but high NNPS curves,whether they are coated with silver film or ***,scintillation screens on FOP have bright images with low NNPS and high NEQ,but have the lowest *** controlling the substrate optical features,CsI(Tl) films can be tailored to suit a given application.
The paper introduces multimodality non-destructive testing and evaluation. Multiphysics integrated NDT&E approaches e.g. dual probe of EMAT and PEC, integrative MFL system, are reviewed. Different strengths and we...
详细信息
Thallium-doped cesium iodide(Cs I(Tl)) screens are widely used in X-ray imaging devices because of the columnar structure of the Cs I(Tl) layer, but few reports focus on the optical role of the substrate in the ...
详细信息
Thallium-doped cesium iodide(Cs I(Tl)) screens are widely used in X-ray imaging devices because of the columnar structure of the Cs I(Tl) layer, but few reports focus on the optical role of the substrate in the screen *** this paper, four substrates including fused silica(Si O2), silver-film coated Si O2, graphite(C) and fiber optic plate(FOP) are used to fabricate Cs I(Tl) screens by thermal evaporation. Their imaging performance is evaluated by relative light output(RLO), modulation transfer function(MTF), normalized noise power spectrum(NNPS) and noise equivalent quanta(NEQ). The results reveal that although Cs I(Tl) film on graphite plate yields images with the lowest light output, it presents relatively higher spatial resolution and better signal-to-noise ***, films on Si O2 plate obtain low MTF but high NNPS curves, whether they are coated with silver film or ***, scintillation screens on FOP have bright images with low NNPS and high NEQ, but have the lowest MTF. By controlling the substrate optical features, Cs I(Tl) films can be tailored to suit a given application.
Gold (Au) and silver (Ag) monometallic nanoparticles (MNPs) and Au-Ag composite nanoparticles (CNPs) were fabricated on silicon wafers by anneal de-wetting the corresponding thin films. The measured reflection spectra...
详细信息
The traditional methods of registering crime scene, such as photographs, sketches, videos and oral descriptions, etc., are lowly efficient and couldn't meet the requirement. In this paper, a new method for crime s...
详细信息
In order to reduce power consumption of sensor nodes and extend network survival time in the wireless sensor network (WSN), sensor nodes are scheduled in an active or dormant mode. A chain-type WSN is fundamental y ...
详细信息
In order to reduce power consumption of sensor nodes and extend network survival time in the wireless sensor network (WSN), sensor nodes are scheduled in an active or dormant mode. A chain-type WSN is fundamental y different from other types of WSNs, in which the sensor nodes are deployed along elongated geographic areas and form a chain-type network topo-logy structure. This paper investigates the node scheduling prob-lem in the chain-type WSN. Firstly, a node dormant scheduling mode is analyzed theoretical y from geographic coverage, and then three neighboring nodes scheduling criteria are proposed. Sec-ondly, a hybrid coverage scheduling algorithm and dead areas are presented. Final y, node scheduling in mine tunnel WSN with uniform deployment (UD), non-uniform deployment (NUD) and op-timal distribution point spacing (ODS) is simulated. The results show that the node scheduling with UD and NUD, especial y NUD, can effectively extend the network survival time. Therefore, a strat-egy of adding a few mobile nodes which activate the network in dead areas is proposed, which can further extend the network survival time by balancing the energy consumption of nodes.
Compressive sampling (CS) has been wildly investigated in wideband signal spectrum sensing. A variety of signal reconstruction algorithms are reported for CS. Usually, the eigenvalues of covariance matrix of compressi...
详细信息
The determination of the effective minimum detectable activity (MDA) of radionuclides by a detection system plays an im- portant role in environmental radiation monitoring. In this study, the responses of an NaI(TI...
详细信息
The determination of the effective minimum detectable activity (MDA) of radionuclides by a detection system plays an im- portant role in environmental radiation monitoring. In this study, the responses of an NaI(TI) airborne γ ray spectrometry (AGRS) system to different radionuclides (137Cs and 131I) were investigated using the Monte Carlo technique. The MDA values were determined under different conditions according to the counting spectra obtained from the Monte Carlo simulation. The equivalent mass thickness method was applied to the Monte Carlo modeling for monitoring ground radiation to reduce sta- tistical uncertainty. The secondary source method was used to monitor both air and ground radiation. A quadratic relationship was found between the MDA and activity concentration. An exponential relationship was found between the MDA and altitude The MDA of a specific radionuclide from external detectors was found to be superior to that obtained from internal detectors under the same conditions. The MDA values in an NaI(Tl) AGRS system under different conditions can be estimated based on the results of this study.
暂无评论