Pregnancy is an intricate process involving substantial physiological changes that impact both maternal and fetal health. In this study, we demonstrate the ability to predict two common symptoms during the third trime...
详细信息
Given two graphs H1 and H2, a graph is (H1, H2)-free if it contains no induced subgraph isomorphic to H1 nor H2. A dart is the graph obtained from a diamond by adding a new vertex and making it adjacent to exactly one...
详细信息
This paper considers one problem of automated proving of MTP inequalities f(x) > 0 over [0, π/2] on boundary points. It suggests one algorithm for symbolic checking for f(0) = 0 or f(π/2) = 0 without use of numer...
详细信息
Hand-eye calibration is the problem of solving the transformation from the end-effector of a robot to the sensor attached to it. Commonly employed techniques, such as AXXB or AXZB formulations, rely on regression meth...
详细信息
ISBN:
(数字)9798350384574
ISBN:
(纸本)9798350384581
Hand-eye calibration is the problem of solving the transformation from the end-effector of a robot to the sensor attached to it. Commonly employed techniques, such as AXXB or AXZB formulations, rely on regression methods that require collecting pose data from different robot configurations, which can produce low accuracy and repeatability. However, the derived transformation should solely depend on the geometry of the end-effector and the sensor attachment. We propose Geometry-Based End-Effector Calibration (GBEC) that enhances the repeatability and accuracy of the derived transformation compared to traditional hand-eye calibrations. To demonstrate improvements, we apply the approach to two different robot-assisted procedures: Transcranial Magnetic Stimulation (TMS) and femoroplasty. We also discuss the generalizability of GBEC for camera-in-hand and marker-in-hand sensor mounting methods. In the experiments, we perform GBEC between the robot end-effector and an optical tracker’s rigid body marker attached to the TMS coil or femoroplasty drill guide. Previous research documents low repeatability and accuracy of the conventional methods for robot-assisted TMS hand-eye calibration. Applying GBEC to repeated calibrations, we obtain transformations with standard deviations of 0.37mm, 0.65mm, and 0.40mm (translation) along x, y, and z axes of the end-effector, respectively. The tool alignment experiments after using GBEC achieve a mean accuracy around 0.2mm in Euclidean distance. When compared to some existing methods, the proposed method relies solely on the geometry of the flange and the pose of the rigid-body marker, making it independent of workspace constraints or robot accuracy, without sacrificing the orthogonality of the rotation matrix. Our results validate the accuracy and applicability of the approach, providing a new and generalizable methodology for obtaining the transformation from the end-effector to a sensor.
●AIM:To investigate a pioneering framework for the segmentation of meibomian glands(MGs),using limited annotations to reduce the workload on ophthalmologists and enhance the efficiency of clinical diagnosis.●METHODS...
详细信息
●AIM:To investigate a pioneering framework for the segmentation of meibomian glands(MGs),using limited annotations to reduce the workload on ophthalmologists and enhance the efficiency of clinical diagnosis.●METHODS:Totally 203 infrared meibomian images from 138 patients with dry eye disease,accompanied by corresponding annotations,were gathered for the study.A rectified scribble-supervised gland segmentation(RSSGS)model,incorporating temporal ensemble prediction,uncertainty estimation,and a transformation equivariance constraint,was introduced to address constraints imposed by limited supervision information inherent in scribble *** viability and efficacy of the proposed model were assessed based on accuracy,intersection over union(IoU),and dice coefficient.●RESULTS:Using manual labels as the gold standard,RSSGS demonstrated outcomes with an accuracy of 93.54%,a dice coefficient of 78.02%,and an IoU of 64.18%.Notably,these performance metrics exceed the current weakly supervised state-of-the-art methods by 0.76%,2.06%,and 2.69%,***,despite achieving a substantial 80%reduction in annotation costs,it only lags behind fully annotated methods by 0.72%,1.51%,and 2.04%.●CONCLUSION:An innovative automatic segmentation model is developed for MGs in infrared eyelid images,using scribble annotation for *** model maintains an exceptionally high level of segmentation accuracy while substantially reducing training *** holds substantial utility for calculating clinical parameters,thereby greatly enhancing the diagnostic efficiency of ophthalmologists in evaluating meibomian gland dysfunction.
Video Corpus Moment Retrieval aims to retrieve the relevant video from a large corpus and localize the corresponding moment within the target video based on a specific query. Existing methods have achieved promising a...
详细信息
Lossy compression has been employed to reduce the unprecedented amount of data produced by today's large-scale scientific simulations and high-resolution instruments. To avoid loss of critical information, state-o...
详细信息
In this paper, the problem of collaborative vehicle sensing is investigated. In the considered model, a set of cooperative vehicles provide sensing information to sensing request vehicles with limited sensing and comm...
详细信息
The main objective of this work was to find the association rules between factors affecting user satisfaction in software project by using an association rule discovery technique. Data from 191 software projects were ...
详细信息
We study the problem of approximate sampling from non-log-concave distributions, e.g., Gaussian mixtures, which is often challenging even in low dimensions due to their multimodality. We focus on performing this task ...
详细信息
暂无评论