Dynamic (average) consensus-based secondary control (SC) is a common and effective method to achieve distributed voltage recovery and load-sharing for multi-bus microgrids (MGs). However, dynamic consensus requires hi...
详细信息
Combined digital measuring current and voltage transformers (DCVTs), developed at Ivanovo State Power Engineering University (ISPEU), are innovative products. The researchers have accumulated some operating experience...
详细信息
Recent years have seen a rising interest in distributed optimization problems because of their widespread applications in power grids, multi-robot control, and regression *** the last few decades, many distributed alg...
Recent years have seen a rising interest in distributed optimization problems because of their widespread applications in power grids, multi-robot control, and regression *** the last few decades, many distributed algorithms have been developed for tackling distributed optimization problems. In these algorithms, agents over the network only have access to their own local functions and exchange information with their neighbors.
Electromagnetic current transformers, invented more than 100 years ago, are today the most widespread type of preliminary current converters, used in organizing metrological channels for commercial and technical elect...
详细信息
ISBN:
(纸本)9798331501105
Electromagnetic current transformers, invented more than 100 years ago, are today the most widespread type of preliminary current converters, used in organizing metrological channels for commercial and technical electricity metering, measuring and relay protection systems. Despite their relatively simple design and modest price, today the question of using unconventional preliminary current converters (Rogowski coils, optical transformers, galvanic-magnetic sensors) is being increasingly raised [1]. This situation is due to the shortcomings of electromagnetic current transformers (CT): large weight and dimensions), explosion and fire hazard, and also saturation of their magnetic conductor in transient modes with the presence of an aperiodic component in short circuiting (SC) current. The phenomenon of saturation leads to significant distortion of the transmitted secondary signal, which in turn may become the cause of overprotection with external SC or delayed protection with internal SC. Russian and international practice in coordinating CT characteristics and relay protection requirements presuppose ensuring correct operation of relay protection systems not only in steady, but also in transient modes with possible saturation of CT magnetic conductors [2]-[5]. At present, testing the correct operation of relay protection and automation devices (RPAD) in transient modes is carried out using the CT saturation time, which under the specific conditions of the location of the CT should be more than the exact current conversion time required for correct operation of the connected RPAD. This time is calculated by special approved methods [2]. Such use of two extreme CT magnetic conductor conditions (saturated/unsaturated), without regard to the current waveform itself may lead to significant inaccuracies in evaluating the correctness of RPAD operation. Fig 1 shows two instances of saturation in one and the same CT in different operating conditions and with the same time be
We propose a novel framework for enhancing robotic adaptability and learning efficiency, which integrates unsupervised trajectory segmentation with adaptive probabilistic movement primitives (ProMPs). By employing a c...
详细信息
Traditional single-satellite passive localization algorithms are influenced by frequency and angle measurement accuracies,resulting in error estimation of emitter position on the order of ***,a single-satellite locali...
详细信息
Traditional single-satellite passive localization algorithms are influenced by frequency and angle measurement accuracies,resulting in error estimation of emitter position on the order of ***,a single-satellite localization algorithm based on passive synthetic aper-ture(PSA)was introduced,enabling high-precision ***,its estimation of azimuth and range distance is considerably affected by the residual frequency offset(RFO)of uncoopera-tive system ***,it requires data containing a satellite flying over the radia-tion source for RFO *** estimating the RFO,an accurate estimation of azimuth and range distance can be carried out,which is difficult to achieve in practical *** LFM radar source passive localization algorithm based on range migration is proposed to address the dif-ficulty in estimating frequency *** algorithm first provides a rough estimate of the pulse repetition time(PRT).It processes intercepted signals through range compression,range interpola-tion,and polynomial fitting to obtain range migration ***,it uses the changing information of range migration and an accurate PRT to formulate a system of nonlinear equations,obtaining the emitter position and a more accurate PRT through a two-step localization *** offset only induces a fixed offset in range migration,which does not affect the changing *** algorithm can also achieve high-precision localization in squint ***,the effectiveness of this algorithm is verified through simulations.
作者:
Suder, JakubMarciniak, TomaszPoznan University of Technology
Faculty of Automatic Control Robotics and Electrical Engineering Institute of Automatic Control and Robotics Division of Electronic Systems and Signal Processing Jana Pawla II 24 Poznań60-965 Poland
The latest EASA recommendations from 2024 indicate the possibility of using machine learning techniques in aerodrome monitoring. The aim of the work was to analyze solutions and prepare FOD (Foreign Object Debris) obj...
详细信息
In this paper, we consider the problem of predicting unknown targets from data. We propose Online Residual Learning (ORL), a method that combines online adaptation with offline-trained predictions. At a lower level, w...
详细信息
Industrial controlsystems (ICSs) are becoming increasingly interconnected as the rapid convergence of information technology (IT) and operation technology (OT) networks, and meanwhile massive attack surfaces have bee...
详细信息
In the development of secondary systems of stations and substations, including relay protection, automation, control, electric power metering and other features, there have recently been qualitative changes related to...
详细信息
暂无评论