With the increasingly stringent IMO emission regulations, the diesel-natural gas dual-fuel engine is gradually applied to ship's powersystems. However, the misfire and unconventional emissions of dual-fuel engine...
详细信息
One of the most significant consequences of short circuits and single phase to earth faults in 6-10 kV cable networks is cable insulation heating, which provides its further deflagration and damage of neighboring powe...
详细信息
ISBN:
(纸本)9781728192703
One of the most significant consequences of short circuits and single phase to earth faults in 6-10 kV cable networks is cable insulation heating, which provides its further deflagration and damage of neighboring power supply systems' elements, which steps up consequential injury. Cable lines overheating during current overload leads to rapid insulation deterioration and cable lines damage rate increasing;similarly, cable heating during single phase to earth faults leads to its transformation to phase-to-phase short circuit, which requires faulted cable line emergency shutdown by relay protection devices operation and, moreover, can aid in cable deflagration when it is installed inside cable tunnels. Reference documents contain several calculation methods for cable line temperature definition both in steady-state and transient modes [1,2]. The main disadvantages of these methods are sufficiently restricted application sphere (only for symmetrical modes) and impossibility for accurate records of thermal conductivity and other thermophysical and geometric parameters of the researched cable line and external environment (soil, air, etc). For the solution of this problem an approach, which was described by F.H. Van Wormer in the 1950s [3] and also mentioned in [4-6], exists. According to this approach, the heated cable line and external environment are presented in the form of equivalent RC-branches, which simulates the process of transition and accumulation of heat. Nevertheless, during composition of such models an issue of computational space size and appropriate sampling rate of elementary RC-branches definition occurs. The model of cable line and external environment on the basis of so-called 'Markov's chains' [for example, 5] is also the case of interest, because it will allow to research qualitative characteristics of the system 'cable line-the external environment' in the context of its electromagnetic heating. The main goal of this research is to compile a digi
This paper studied the design of a predictive current control strategy with fault tolerance and reactive power minimization applied to a multi-modular topology based on indirect 2-level matrix converters fed by a six-...
详细信息
Energy storage is one of the key means for improving the flexibility,economy and security of power *** is also important in promoting new energy consumption and the energy ***,energy storage is expected to support dis...
详细信息
Energy storage is one of the key means for improving the flexibility,economy and security of power *** is also important in promoting new energy consumption and the energy ***,energy storage is expected to support distributed power and the micro-grid,promote open sharing and flexible trading of energy production and consumption,and realize multi-functional *** recent years,with the rapid development of the battery energy storage industry,its technology has shown the characteristics and trends for large-scale integration and distributed applications with multi-objective *** a grid-level application,energy management systems(EMS)of a battery energy storage system(BESS)were deployed in real time at utility control centers as an important component of power grid *** on the analysis of the development status of a BESS,this paper introduced application scenarios,such as reduction of power output fluctuations,agreement to the output plan at the renewable energy generation side,power grid frequency adjustment,power flow optimization at the power transmission side,and a distributed and niohile energy storage system at the power distribution *** studies and application status of a BESS in recent years were *** energy management,operation control methods,and application scenes of large-scale BESSs were also examined in the study.
Network on Chip (NoC) is a communication subsystem between various IPs interconnected through an on-chip router inside a single chip. The on-chip interconnection infrastructure connects the different intellectual prop...
详细信息
The substation is the core facility of the power system. The interaction and coordination of different equipment in the protection and monitoring system(PMS) directly affects the working efficiency and stable operatio...
详细信息
The article is devoted to the analysis of the possibilities of improving the methodology for selecting the operation parameters of the longitudinal differential protection of a power transformer when using new types o...
The article is devoted to the analysis of the possibilities of improving the methodology for selecting the operation parameters of the longitudinal differential protection of a power transformer when using new types of current transformers such Rogowski Coils, optical current transformers (including digital ones) and their combinations with traditional current transformers. The results of studies of the characteristics of digital transformers are presented, also the heat, repeatability of construction and continuous operating conditions influence on it are shown. Based on anlysis for these studies possible improvements in the methodology for selecting the operation parameters of the differential protection of the transformer are proposed. These improvements can increse the sensitivity and reliability for differential transformer protection.
Variable phase-pole machines possess the capability to expand their operational range by employing magnetic pole change while adhering to the same electrical voltage and current limits. This paper proposes a strategy ...
详细信息
The growing demand for energy-saving lamps highlights critical limitations in traditional LED secondary optics, which reduce energy efficiency and complicate heat dissipation - a key factor in LED lamp longevity. This...
详细信息
The paper presents a model-based approach to the design of power electronic devices. Ensuring the output performance of electronic converters is extremely important for achieving the desired quality of the energy conv...
详细信息
暂无评论