In view of the uncertainty and intermittency of wind power, this paper presents a bi-objective short-term operation model to manage wind-thermal power systems. This model takes into account both the offer cost and emi...
详细信息
Vector control of Induction Motor (IM) is usually used in speed regulating system. However, in wind power generation system, speed regulator is not needed. On the contrary, there is only a stator current closed-loop i...
详细信息
ISBN:
(纸本)9781479984671
Vector control of Induction Motor (IM) is usually used in speed regulating system. However, in wind power generation system, speed regulator is not needed. On the contrary, there is only a stator current closed-loop in the traditional wind power generation system. The torque set by the turbine controller is controlled indirectly by closed-loop current control. However, the torque control accuracy is low because of the influence of the parameters. Torque closed-loop control can improve the control accuracy, but the feedback torque needs be observed. In this paper, a real-time stator flux observation method based on minimum order flux observer is proposed, based on which the stator flux and torque are calculated. The proposed stator flux observer avoids the flaws of the traditional pure integral strategy, such as saturation, phase shift, amplitude deviation, and so on. Meanwhile, the proposed stator flux observer is robust to parameters, namely, the preciseness of the observed torque is almost not affected by mutual inductance. Experiments of 130KW IM validate the performance of the proposed method.
This paper mainly discusses the remote tracking problem with partly quantized information and packet-dropout. Since the network exists between the remote plant and the local plant, any information transmitted between ...
详细信息
ISBN:
(纸本)9781479947249
This paper mainly discusses the remote tracking problem with partly quantized information and packet-dropout. Since the network exists between the remote plant and the local plant, any information transmitted between each other will experience the quantization errors and may be lost. In this situation, the controller of the local system needs to consider both the exact local information and the inaccurate remote information. A state feedback controller is adopted and the theorems to design such controller are given in terms of bilinear matrix inequalities(BMIs). Moreover, an algorithm is proposed and these BMIs are converted into a convex optimization problem. Finally, the efficiency of the proposed method is demonstrated by a simulation example.
This paper investigates the feasibility of operating a wind turbine with lightweight tower in the full load region exploiting an adaptive nonlinear controller that allows the turbine to dynamically lean against the wi...
详细信息
ISBN:
(纸本)9781479917730
This paper investigates the feasibility of operating a wind turbine with lightweight tower in the full load region exploiting an adaptive nonlinear controller that allows the turbine to dynamically lean against the wind while maintaining nominal power output. The use of lightweight structures for towers and foundations would greatly reduce the construction cost of the wind turbine, however extra features ought be included in the control system architecture to avoid tower collapse. An adaptive backstepping collective pitch controller is proposed for tower point tracking control, i.e. to modify the angular deflection of the tower with respect to the vertical axis in response to variations in wind speed. The controller is shown to guarantee asymptotic tracking of the reference trajectory. The performance of the control system is evaluated through deterministic and stochastic simulations including an extreme wind gust event, and the feasibility of stabilizing the tower position while maintaining the rated power output is shown.
In this paper, we consider the robust fault tolerant control of the distributed networked control systems(DNCSs). In DNCSs, sub-systems are connected with each other through a communication network. Each sub-system ha...
详细信息
ISBN:
(纸本)9781479947249
In this paper, we consider the robust fault tolerant control of the distributed networked control systems(DNCSs). In DNCSs, sub-systems are connected with each other through a communication network. Each sub-system has its own sensor, controller, actuator and quantizer. The output of each sub-system will be transmitted to all other sub-systems through the network. As a result, quantization errors and packet-dropouts cannot be avoided. We also consider the actuator faults situations, including outage, loss of effectiveness and impulse which is modeled by a Markov chain in this paper. A mode-based static output feedback controller is proposed to stable the DNCSs and to meet the robust H-inf performance. Finally, a simulation example is given to illustrate the effectiveness of the proposed method.
Furnace exit gas temperature(FEGT) is the key parameter in the furnace ash fouling monitoring system. Since the standard least squares support vector machine(LSSVM) is not suitable for online identification and contro...
详细信息
ISBN:
(纸本)9781479947249
Furnace exit gas temperature(FEGT) is the key parameter in the furnace ash fouling monitoring system. Since the standard least squares support vector machine(LSSVM) is not suitable for online identification and control of FEGT,a novel CM-LSSVM-PLS method is proposed to predict FEGT in this paper. In the process of CM-LSSVM-PLS method, c-means cluster(CM) algorithm is used to partition the training data into several different subsets by considering the characteristics of operational data. Submodels are subsequently developed in the individual subsets based on LSSVM method. Partial least squares algorithm(PLS) is employed as the combination strategy. The online updating algorithm is then applied to the CM-LSSVM-PLS model. The proposed online model is verified through operation data of a 300 MW generating unit. The simulation results show that the proposed online updating model is effective for online FEGT forecasting.
To meet the requirements for power grid data sharing and model maintenance, this paper proposes a cooperative modeling scheme between transformer substations and the control center. The implementation is based on char...
详细信息
Power grid modeling, data maintenance and management in substation and control center are based on IEC61850 standard and IEC61970 standard respectively. The difference between the two standards inevitably affects the ...
详细信息
In this paper a new approach to data stream evolving fuzzy model identification is given. The structure of the model is given in the form of Takagi-Sugeno and the partitioning of the input-output space is obtained usi...
详细信息
This works proposes an electrocardiogram based approach for left ventricle hypertrophy (LVH) classification. LVH classification is based on features extracted from the ECG signal, where the main features are the ones ...
详细信息