Parallel gaps,as a new mode of "channel" type lightning protection,can do it with the sub insulator arc distance to effectively protect the insulator,but the corresponding line tripping rate will be affected...
详细信息
Parallel gaps,as a new mode of "channel" type lightning protection,can do it with the sub insulator arc distance to effectively protect the insulator,but the corresponding line tripping rate will be affected because of this;Development method based on the leader in this paper the calculation method of the lightning path,the typical used tower of guangzhou trip rate change after the application of parallel gap situation has carried on the analysis,got a short distance and adopt reasonable reinforced insulation,the trip rates did not rise significantly.
We investigate synchronization in a population of mobile pulse-coupled agents with a view towards implementations in swarm-robotics systems and mobile sensor networks. Previous theoretical approaches dealt with range ...
详细信息
We investigate synchronization in a population of mobile pulse-coupled agents with a view towards implementations in swarm-robotics systems and mobile sensor networks. Previous theoretical approaches dealt with range and nearest-neighbor interactions. In the latter case, a synchronization-hindering regime for intermediate agent mobility is found. We investigate the robustness of this intermediate regime under practical scenarios. We show that synchronization in the intermediate regime can be predicted by means of a suitable metric of the phase response curve. Furthermore, we study more-realistic K-nearest-neighbor and cone-of-vision interactions, showing that it is possible to control the extent of the synchronization-hindering region by appropriately tuning the size of the neighborhood. To assess the effect of noise, we analyze the propagation of perturbations over the network and draw an analogy between the response in the hindering regime and stable chaos. Our findings reveal the conditions for the control of clock or activity synchronization of agents with intermediate mobility. In addition, the emergence of the intermediate regime is validated experimentally using a swarm of physical robots interacting with cone-of-vision interactions.
This paper presents a fully automated procedure for controller synthesis for a general class of multi-agent systems under coupling constraints. Each agent is modeled with dynamics consisting of two terms: the first on...
详细信息
By calling MATLAB calculation engine function library,associated simulation between Power System Analysis Software Package(PSASP) and MATLAB can be realized in parallel and serial *** could use different timing sequen...
详细信息
By calling MATLAB calculation engine function library,associated simulation between Power System Analysis Software Package(PSASP) and MATLAB can be realized in parallel and serial *** could use different timing sequence from PSASP,and mixed step simulation can be *** calculation method was used in a 10-nodes power system case for the modeling and simulation of automatic Voltage Regulator(AVR),and the correctness of the proposed approach is *** this foundation,the electromechanical transient model of Static Var Generator(SVG) was founded with MATLAB/Simulink,and it is of universal applicability and *** inner inverter model can also be used in general grid-connection simulating models of wind power generator,photovoltaic generation,energy storage,***,simulation and analysis for grid-connected wind farm by introducing the SVG model into PSASP were carried out via the proposed associated simulation method above,and the correctness of the model is verified via the calculation *** research results can be used to do assistant analysis for reactive voltage of grid-connected new energy power generation.
The paper deals with issue of parallel connection of more DC/DC converters. The article contains theoretical overview of one group of methods designed for proper functioning of parallel connected converters. The main ...
详细信息
ISBN:
(纸本)9781538617519
The paper deals with issue of parallel connection of more DC/DC converters. The article contains theoretical overview of one group of methods designed for proper functioning of parallel connected converters. The main advantage of referred methods is their simplicity. In some cases they fully satisfy requirements and they can be used for correct functioning of parallel power stages. Following part is dedicated to analysis of the one method by computer simulations. Analyzed method with current feedback has proved to be operational. Current-sharing can be ensured if current reference value is set at correct value for certain load. The results of the simulation showed that for 5Ω load and 20V of required output voltage is the 1A of reference current value just right. But when output resistive is increased, reference current value should be set more tightly (at the lower value). However then it can cause fall of the output voltage. It is why the droop methods increase current-sharing abilities, but makes worse output voltage regulation.
This paper considers the problem of estimating the parameters of a signal using time-varying thresholded noisy one-bit measurements. The problem is shown to be deterministically identifiable under reasonable condition...
详细信息
Wind power generations (WPGs) are different from traditional generations for their considerable fluctuations. It is challenging to describe the status of a system with power fluctuation injections, especially when con...
详细信息
The linearised Navier-Stokes equations form the basis of many models used in the design of feedback controllers for fluid flows. This set of coupled, partial differential algebraic equations (PDAEs) presents several n...
详细信息
The linearised Navier-Stokes equations form the basis of many models used in the design of feedback controllers for fluid flows. This set of coupled, partial differential algebraic equations (PDAEs) presents several numerical problems upon spatial discretisation, and whilst these problems are relatively well understood in the computational fluid dynamics (CFD) community, little attention has been paid to their system theoretic model analogies. This paper considers the problem known in the fluid dynamics community as the `checkerboard instability', and reconciles current understanding of this phenomenon from a systems' theory perspective, whereby frequency domain analysis elegantly explains the phenomenon. We report work in progress on deriving a discretised version of the linearised Navier-Stokes equations that avoids this problem.
With the rapid development of distributed energy resources (DERs), it is of vital importance to develop a well-designed transmission cost allocation scheme to reflect the contributions of DERs to the power system. In ...
详细信息
This article presents the basic principles of operation for model predictive control (MPC), a control methodology that opens a new world of opportunities. MPC is a powerful technique that can fulfill the increased per...
详细信息
This article presents the basic principles of operation for model predictive control (MPC), a control methodology that opens a new world of opportunities. MPC is a powerful technique that can fulfill the increased performance and higher efficiency demands of power converters today. The main features of this technique are presented as well as the MPC strategy and basic elements. The two main MPC methods for power converters [continuous-control-set MPC (CCS-MPC) and finite-control-set MPC (FCS-MPC)] are described, and their application to a voltage-source inverter (VSI) is shown to illustrate their capabilities. This article tries to bridge the gap between the powerful but sometimes abstract techniques developed by researchers in the control community and the empirical approach of power electronics practitioners.