Demmand Side Management (DSM) is now an important consideration for electric power utilities. DSM in general refers to any activity adopted by an electric utility that ultimately changes the utility's system load ...
详细信息
As a series FACTS device based on Voltage Source Converter (VSC), Static Series Synchronous Compensators (SSSC) can optimize power flow and improve powersystem stability by controlling the line impedance rapidly. Acc...
详细信息
The comparison between Hilbert space based power theory and three other power theories including traditional power theory , instantaneous power theory put forward by Akagi and Fryze power theory are analyzed in this p...
详细信息
The location and sizing of distribution substations integrated with urban spatial information is a optimization problem which primary characteristics are the existence of many suboptimal cost peaks and the solution sp...
详细信息
Real time test is a necessary step for the control device of equipment before it is installed in powersystem. In this paper, a closed-loop test platform which is based on Real Time Digital Simulator (RTDS) is establi...
详细信息
ISBN:
(纸本)9787506292214
Real time test is a necessary step for the control device of equipment before it is installed in powersystem. In this paper, a closed-loop test platform which is based on Real Time Digital Simulator (RTDS) is established to test the performance of FACTS device controller. In this paper, Static Var Compensator (SVC) which is installed in a power plant is used for damping Sub Synchronous Oscillation (SSO) excited by fixed series compensator installed in the transmission line which is to improve the power transfer capability. The control approach, operation mode and the install location of SVC are studied in this paper and the real controller performance has been verified by the proposed test platform. Beside, this platform can also used for the test of performance of other FACTS devices controller.
Concrete-polluted silicone rubber (SIR) insulators are common nature-polluted insulators. A type of concrete-polluted SIR insulators with different content of concrete was evaluated. The flashover voltage of concrete-...
详细信息
An improved differential evolution (IDE) algorithm was presented for powersystem load economic dispatch (ED), a classical nonconvex, nonlinear, combinational optimization problem. Despite for its simplicity and high-...
详细信息
An improved differential evolution (IDE) algorithm was presented for powersystem load economic dispatch (ED), a classical nonconvex, nonlinear, combinational optimization problem. Despite for its simplicity and high-efficiency, differential evolution (DE) algorithm is prone to local optimal solution sometimes. Based on analysis of DE searching mechanism, IDE algorithm adopts adaptive control parameters according to swarms' distribution condition and the overlapping individuals undertake chaotic searching to improve its robust and global optima searching capability. The proposed IDE algorithm was tested on two systems consisting of 3, 40 and 69 thermal units whose incremental fuel cost function took into account the valve-point effects. The results indicate that IDE algorithm outperforms DE, GA, and PSO algorithms in solving load dispatch problems.
Distinguishing the transferring fault is one of difficulties for transformer differential protection. According to CT (current transformer) saturation characteristic, a new algorithm of distinguishing the transferring...
详细信息
Distinguishing the transferring fault is one of difficulties for transformer differential protection. According to CT (current transformer) saturation characteristic, a new algorithm of distinguishing the transferring fault is put forward. As the primary current of CT crosses zero, a small linear transmission part of CT would appear, no matter how CT saturated. Based on this characteristic, the waveform of the differential current would expose discontinuous parts when an external fault occurred;in contrast, this phenomenon would not appear for an internal fault. The morphological gradient is adopted to deal with the waveform between two adjacent extremal points of the differential current. By dividing the gradient waveform into three parts and calculating each part's area, the discontinuous in the differential current could be detected according to the relative size of three above areas. By judging whether the discontinuous parts are existed in the differential current, the transferring faults could be easily distinguished. Simulation results show that this algorithm can distinguish the internal fault, external fault and the fault transferred from the external to the internal under the condition of CT saturation.
Aim at the stability problem of multi-infeed direct current (MIDC) systems, voltage source converter based HVDC (VSC-HVDC) was applied to MIDC systems for improving the voltage characteristic of common AC bus in MIDC ...
详细信息
Aim at the stability problem of multi-infeed direct current (MIDC) systems, voltage source converter based HVDC (VSC-HVDC) was applied to MIDC systems for improving the voltage characteristic of common AC bus in MIDC systems. A physical model of a dual-infeed HVDC and VSC-HVDC system was set up, and its mathematical model was developed. The rectangular coordinate form of VSC's power transmission equations was deduced through coordinate conversion. Based on the inverse system method for multivariable nonlinear control, the nonlinear controllers of VSC-HVDC system were designed. Simulation results performed on PSCAD/EMTDC show that the designed nonlinear controllers of VSC-HVDC can improve effectively the dynamic character of VSC-HVDC system, stabilize effectively the voltage of dual-infeed HVDC and VSC-HVDC system when AC side is disturbed, reduce the probability of commutation failure in the inverter of HVDC systems, and increase the operation reliability of HVDC systems.
The characteristics of voltage modal transformation based on fault component in fault location and protection location are discussed in detail with regard to the changes of the system parameters and fault types. A new...
详细信息
The characteristics of voltage modal transformation based on fault component in fault location and protection location are discussed in detail with regard to the changes of the system parameters and fault types. A new phase-selector based on voltage modal fault component is proposed. It uses voltage fault component and works fast after a fault occurs. A fault selection scheme is also proposed to solve problems of sensitivity as faults located on remote end of transmission lines. The simulation results of ATP and MATLAB show the feasibility of the scheme.
暂无评论