With the development of grid- interconnection and the commission of power electronic devices, the dynamic behaviors of powersystems become more and more complex. Once there is a disturbance, large area of outages mig...
详细信息
ISBN:
(纸本)0863412467
With the development of grid- interconnection and the commission of power electronic devices, the dynamic behaviors of powersystems become more and more complex. Once there is a disturbance, large area of outages might be occurred without effective transient stability analysis and control methods. The advent of WAMS gives a new way to transient stability analysis. In this paper, a new criterion of transient stability assessment is proposed based on COI system. Finally, numerical simulations are conducted on IEEE-9 bus system to demonstrate the effectiveness of the criterion.
This paper put forward to an interactive flexible SCADA system in which information shared, on the basis of analyzing and summarizing the defections of former SCADA. It not only solves the interaction of data and func...
详细信息
With the increasing of grid-size, the problems of powersystem stability become more and more prominent. Meanwhile, it is very urgent to achieve quantitative stability analysis for the operation of electricity market....
详细信息
With the increasing of grid-size, the problems of powersystem stability become more and more prominent. Meanwhile, it is very urgent to achieve quantitative stability analysis for the operation of electricity market. The advent of WAMS (wide area measurement system) provides a new way for studying multi-swing stability of powersystem. In this paper, a curvature vector of an electric machine kinetic energy-power angle curve is defined firstly, and then the relationship between the defined curvature vector and the corresponding individual machine stability is analyzed. The validity of the relationship is proved in detail. Therefore, the curvature vector of kinetic energy-power angle curve as a new stability assessment function is proposed. A new criterion of stability assessment based on WAMS is proposed. Numerical simulations are conducted on IEEE-9 bus system and 6 machines-22 bus system of China EPRI to demonstrate the effectiveness of this criterion.
Reasonable black-start plans are necessary for restoring the powersystem quickly. Based on analytic hierarchy process (AHP) and data envelopment analysis (DEA), a novel strategy for assessing black-start plans is pro...
详细信息
ISBN:
(纸本)0863412467
Reasonable black-start plans are necessary for restoring the powersystem quickly. Based on analytic hierarchy process (AHP) and data envelopment analysis (DEA), a novel strategy for assessing black-start plans is proposed in this paper. First, the objective and requirements of restoration are analyzed thoroughly. So, assessment hierarchy is divided appropriately through employing AHP and the relative importance of assessment criteria is identified. Secondly, plans are compared with regard to different assessment criteria by means of DEA. Finally, plans are assessed comprehensively through integrating results of first two steps. The application to a practical powersystem verifies that the strategy could provide dispatchers more exact decision references.
There are many PSS and additive damping controllers of FACTS in modern powersystems. As the interaction among controllers is important to powersystem stability, the damping characteristic study of such system with m...
详细信息
ISBN:
(纸本)0863412467
There are many PSS and additive damping controllers of FACTS in modern powersystems. As the interaction among controllers is important to powersystem stability, the damping characteristic study of such system with multicontroller is necessary. In this paper the AC/DC mixed powersystem with PSS, DCM and additive damping controller of TCSC is analyzed by the signature analysis method, the damping characteristic of complex powersystem is gained and the effect of adjustable parameter of controllers on damping and the interaction among controllers are studied. The conclusions we have drawn will have important guiding significance to the coordination and stability control.
HVDC transmission lines system has some advantages, but it can generate an effect on the environment nearby due to the corona, especially the ionized field. Based on the electromagnetic field theory, a simple method t...
详细信息
ISBN:
(纸本)3952299049
HVDC transmission lines system has some advantages, but it can generate an effect on the environment nearby due to the corona, especially the ionized field. Based on the electromagnetic field theory, a simple method to analyze the ionized field generated from the bundled conductors of bipolar lines is proposed. And then, after the validity of the method is testified, some examples are analyzed and some conclusions are drawn finally. The results have been used in the design of ±800kV HVDC transmission lines system in China.
In this paper, a global control scheme for improving transient stability of powersystems by thyristor controlled braking resistor is proposed. According to the hierarchical control theory of large-scale system princi...
详细信息
ISBN:
(纸本)0863412467
In this paper, a global control scheme for improving transient stability of powersystems by thyristor controlled braking resistor is proposed. According to the hierarchical control theory of large-scale system principle, the control structure is organized into a two-layer controller. Two-level co- state prediction algorithm is used during optimization of parameters of the controller. The lower layer is composed of decentralized local feedback controllers, each of which takes local feedback signal and controls its connected generator. In the upper layer a global controller is designed to enhance the effectiveness of decentralized local controllers. The global controller coordinates local controllers by generating remote feedback signals which ensuring the global optimal solution of the overall system transient performance. The proposed control scheme can guarantee fast and accurate control actions of local controllers when a powersystem is subjected to large disturbances. Simulation results show the effectiveness of the proposed control scheme.
The paper presents the dynamic model of doubly fed induction generator (DFIG) including the mechanical model, the generator model and the PWM voltage source converter model. The mechanical model uses two-mass model, a...
详细信息
A detailed user-defined (UD) reactive power control (RPC) model of HVDC has been developed in powersystem Analysis Software Package (PSASP). The UD RPC model, as one part of UD HVDC models which have been set up base...
详细信息
ISBN:
(纸本)0863412467
A detailed user-defined (UD) reactive power control (RPC) model of HVDC has been developed in powersystem Analysis Software Package (PSASP). The UD RPC model, as one part of UD HVDC models which have been set up based on the control system of Three Gorges-Changzhou project, includes reactive power generation calculation, reactive power consumption calculation, reactive power control strategies and converter reactive power regulator strategies. Each part of the UD RPC model and its guidelines are presented in this paper. Case studies are carried out on the WEPRI-7 system whose embedded HVDC models are replaced by the UD HVDC models. The simulation results show the correctness and necessity of the UD RPC model for AC/DC hybrid system interaction and stability analysis.
A method of the thyristor rapi switched capacitors is presented in this paper, which breaks through the bondage of the conventional methods. In addition, a novel algorithm of two time reactive power has been presented...
详细信息
ISBN:
(纸本)0863412467
A method of the thyristor rapi switched capacitors is presented in this paper, which breaks through the bondage of the conventional methods. In addition, a novel algorithm of two time reactive power has been presented, with which reactive power can be calculated fast. Meanwhile, with microcomputer synchronous phase lock technology, quick switching without transition can be realized, dynamic reactive compensation for impact load can be achieved, and the total response time is shorter than 16 ms. This technology not only can compensate reactive current dynamically but also can improve the voltage waveform to a certain extent. In the end, the type test waveforms and the users' field test waveforms are given to show the validity and effectiveness of this technology. This method is an effective way to improve power quality.