Both peak-regulating of the connected power grid using VSC-HVDC in normal or emergency power support each other in the case of both sides of AC system have fault via VSC-HVDC, are dependent on its rapid reversal of po...
详细信息
A three-terminal DC transmission system based on modular multilevel converter (MMC) is developed to solve the problem of power supply for distributed islands or cities. The system, with flexible features, may generate...
详细信息
Studying the HVDC typical fault-the commutation failure and its protection measures will give some guidance for HVDC engineering, also, it will improve the AC-DC powersystem safety and reliability with great signific...
详细信息
This paper proposes a high-power controllable current quality disturbance generator, which is composed of multiplex cascade H bridge modules, and simulates current quality problems, such as positive and negative curre...
详细信息
This paper proposes a high-power controllable voltage quality disturbance generator, which is composed of multiplex cascade H bridge modules, and simulates many types of voltage quality problems, such as voltage swell...
详细信息
The estimation of operating reserve to guarantee the systemsecurity and economic operation is an important task in powersystem operation. With the rapid increase of wind power installation and its large scale integr...
详细信息
The aim of relay protection is to isolate the fault zone or device and guarantee the systemsecurity. The primary protection and backup protection is in cooperation relationship, and backup one could not be canceled b...
详细信息
ISBN:
(纸本)9780889869059
The aim of relay protection is to isolate the fault zone or device and guarantee the systemsecurity. The primary protection and backup protection is in cooperation relationship, and backup one could not be canceled because of the DC power supply failure in substation. The fault location algorithm based on wide area information is one of the key points for novel wide area backup protection. By use of the synchronized phasor data uploaded by PMUs, the process of locating fault could be implemented in real-time or near real-time level. In this paper, based on Bayesian theory, we have studied the fault location in wide area backup protectionsystems. The simulation experiments have confirmed that the detection of fault can be resolved exactly and effectively by Bayesian theory.
To deal with reactive power optimization problem,an adaptive Niche Particle Swarm Optimization algorithm (ANPSO) is *** Evolution algorithm (DE) is easy to use and has the advantages of strong robustness,but its effic...
详细信息
To deal with reactive power optimization problem,an adaptive Niche Particle Swarm Optimization algorithm (ANPSO) is *** Evolution algorithm (DE) is easy to use and has the advantages of strong robustness,but its efficiency is limited and probably to fall into local optimum because the population loss of diversity after several *** introduces niche-sharing mechanisms to change the individual values and accelerates to eliminate individuals which have low *** radius can also be adjusted adaptively on the basis of the relative distance between individuals which reflect the aggregation of *** the above method,algorithm's global searching ability is *** proposed algorithm is tested on a realistic planning project and the results show its better performance on celerity,accuracy and efficiency.
A multi-input and multi-output linear model of multi-machine powersystem was established based on perturbation analysis, and the complex torque coefficient of target generator was deduced in detail. From a mathematic...
详细信息
A multi-input and multi-output linear model of multi-machine powersystem was established based on perturbation analysis, and the complex torque coefficient of target generator was deduced in detail. From a mathematical perspective, the meaning of complex torque coefficient was explained. Meanwhile, the reasonability about non-target generators being equivalent to different models was discussed when investigating subsynchornous oscillation phenomenon in a multi-generator system. The results showed that the complex torque coefficient method was suitable for multi-generator system and the procedure of simplifying non-target generator as single rigid body or voltage sources with fixed frequency was inappropriate. Then a case study of IEEE second benchmark verified the conclusions above.
This paper proposes a high-power controllable current quality disturbance generator, which is composed of multiplex cascade H bridge modules, and simulates current quality problems, such as positive and negative curre...
详细信息
This paper proposes a high-power controllable current quality disturbance generator, which is composed of multiplex cascade H bridge modules, and simulates current quality problems, such as positive and negative current distrubance, current fluctuation, harmonic current and so on. The device adopts a topology with decoupling fundamental and harmonic current. A power module parallel-connected on the fundamental connection reactance outputs harmonic current, while cascade fundamental power modules generate fundamental and low order harmonic current, which realizes decoupling control of fundamental and harmonic current. This paper proposes the control strategies of all types of current disturbances, and the Ether Cat-based controller. Finally, a 10 k V/1MVA controllable current quality disturbance generator has been created. The experiment result proves that the proposed main circuit topology, control strategy and Ether Cat-based controller are feasible and efficient. The emergence of this device creates a fundamental platform for measurement, analysis, evaluation and control of current quality in grid.