In this paper, a new method of hybrid non-linear state estimation with PMU is proposed. Firstly, the voltage phasor measurements are transformed into indirect equivalent branch current measurements, with which the con...
详细信息
More and more IEDs have been commissioned in powersystems, such as digital relays, PMUs, metering and control devices, fault recorders and so on. Once there is a disturbance (for example, fault, low-frequency oscilla...
详细信息
PSS and DC modulation (DCM) controllers are effective in suppressing low frequency oscillations of AC/DC mixed powersystems, but controllers designed by conventional method for a certain oscillation pattern of a give...
详细信息
Simulation assessment of error and veracity is the precondition in powersystemdynamic simulation validation that is directly related to powersystem stability. Own to the applications of Wide Area Measurement system...
详细信息
Reasonable modeling and control is of significance for theory study and practical operation of doubly-fed variable speed constant frequency (DFVSCF) wind power generator. Two sorts of simulation models called no-load ...
详细信息
A novel scheme based on equivalent instantaneous leakage inductance (EILI) to distinguish inrush currents from internal fault currents in power transformers is proposed, which is derived from the circuit differential ...
详细信息
This paper presents a novel scheme based on grille fractal for distinguishing between inrush currents and internal fault currents in transformers, which is derived from the singularity detection in the waveforms. Firs...
详细信息
The performance of VSC-HVDC system depends on the parameters of control system, and usually PI controllers have been used to adjust system to fulfill desired objectives. However, the optimization methods for PI contro...
详细信息
This paper analyzed the operating principles and power and torque characteristics of the wind turbine and the direct current motor (DC motor), and investigated the operating characteristics of the wind turbine compare...
详细信息
This paper analyzed the operating principles and power and torque characteristics of the wind turbine and the direct current motor (DC motor), and investigated the operating characteristics of the wind turbine compared to that of the DC motor. The torque imitation scheme, which has good performance and high feasibility, together with the whole wind turbine imitation system, was provided. The wind turbine imitation system includes not only a hardware platform composed of PC, data-collection board and thyristor-based velocity-regulator, but also monitor software of wind turbine imitation. The experimental results of different occasions verify the correctness and feasibility of the wind turbine imitation scheme proposed in this paper, which provided a valid idea for wind turbine imitation and investigation of wind power generation techniques in the laboratory.
Current transformer saturation has always been one of the major problems of degraded reliability of the transformer differential protection. The ratio restraining differential characteristic can enable the transformer...
详细信息
Current transformer saturation has always been one of the major problems of degraded reliability of the transformer differential protection. The ratio restraining differential characteristic can enable the transformer protection to be immune to the mal-operation in the external fault to some extent. But how to unblock the differential protection rapidly for the transferring fault form an external one to an internal one has become a new problem. This paper presents a new method of unblocking the differential protection for the transferring fault. In the method proposed, current comparison is made between he maximal value of the integrated negative phase sequence component of the current on the two sides of a transformer and the integrated negative phase sequence component of the differential current. Based on the current comparison results, the method proposed can not only accurately identify the internal fault and the external one, but also the transferring fault developed from the external fault to the internal one. Simulation results of ATP validate the effectiveness of the method proposed.
暂无评论