A power quality evaluation method combining extenics and AHP(Analytic Hierarchy Process) is presented. Three matter-element models are set based on power quality analysis using matter -element theory of extenics, and ...
详细信息
A power quality evaluation method combining extenics and AHP(Analytic Hierarchy Process) is presented. Three matter-element models are set based on power quality analysis using matter -element theory of extenics, and quantified to form relationship matrix using relation-function theory of extenics. The target weights are figured out using AHP. The final quantitative grade of the power quality is calculated based on relation-matrix and target weights. The power quality level of synthetic evaluation is obtained by combining the relationship matrix and the target weights. As an example, the power quality of PCC(the Point of Common Coupling) is evaluated, which shows that, the proposed method can evaluate power quality quantitatively and qualitatively and distinguishes different power quality levels effectively.
Cascading trips caused by flow transferring are the crucial reason of a lot of well-known blackouts. It threatens the security and reliability of powersystems severely. A wide area measurement system (WAMS) based con...
详细信息
Cascading trips caused by flow transferring are the crucial reason of a lot of well-known blackouts. It threatens the security and reliability of powersystems severely. A wide area measurement system (WAMS) based control strategy to prevent cascading trips caused by flow transferring is presented. By analysis of the relationship of node injection current and branch current of network, the principle of control nodes selection of load shedding and generator tripping and the calculation method of control quantity are proposed. The corresponding of the control strategy is also given. The calculation method of branch current before the control action during powersystemdynamic process is given. The simulation results of 10-generator 39-bus New England system show that the control strategy can prevent cascading trips effectively.
The researches on measurement-based load modeling have been continued for more than twenty years in China. However, since lacking of system measured data of major disturbance, it is doubtful for load model generalizat...
详细信息
For accurate simulation of voltage stress on secondary circuits caused by very fast transient over-voltage in gas insulated substation (GIS), a sophisticated modeling of potential and current transformers (PT/CT) is o...
详细信息
For accurate simulation of voltage stress on secondary circuits caused by very fast transient over-voltage in gas insulated substation (GIS), a sophisticated modeling of potential and current transformers (PT/CT) is of vital importance. A new method is proposed to setup high frequency two-port circuit model of PT based on scattering parameters. First, the scattering parameters of PT are transformed in to Y-parameters and equivalent 'π' circuit model could be established. Second, vector fitting method is used to approximate admittances of equivalent 'π' circuit model by rational functions. At last, a circuit synthesis method for rational functions is applied to build circuit model. The simulation and measurement results are presented, which confirmed validity of the proposed model. The proposed method is effective and general, and overcomes the limitation of former methods. The model setup by this method can make simulation more accurate of conductive coupling through PT/CT in GIS.
Resonance mechanism is one of the theories that interpret powersystem low frequency oscillation. According to the resonance mechanism, power disturbance of prime mover can arouse powersystem forced low frequency osc...
详细信息
Resonance mechanism is one of the theories that interpret powersystem low frequency oscillation. According to the resonance mechanism, power disturbance of prime mover can arouse powersystem forced low frequency oscillations. Therefore, the causes of turbine power disturbance were analyzed. The coupling model between thermodynamicsystem of plant and powersystem was set up by MATLAB. The possibility of combustion ratio of boiler and control valve of governing system disturbance inducing the variation of turbine power was researched in detail. The simulation results indicate that powersystem low frequency oscillations of resonance mechanism might be caused by the disturbance of control valve, when it's frequency is consistent with or close to powersystem natural oscillations frequency. Because of the biggish inertia of boiler, the disturbance of combustion ratio cannot invoke powersystem low frequency oscillation of resonance mechanism.
Cascading trips caused by flow transferring are the crucial causation of a lot of well-known blackouts. It severely threatens the security and reliability of powersystems. Flow transferring relativity factor (FTRF) i...
详细信息
Cascading trips caused by flow transferring are the crucial causation of a lot of well-known blackouts. It severely threatens the security and reliability of powersystems. Flow transferring relativity factor (FTRF) is extended from single branch removal event to multi-branches removal event. According to refraction and reflection process of flow transferring, the calculation formula of FTRF for multi-branches chain removal event is deduced. Moreover, by using the relationship of node injection currents and branch currents, a method of post-fault branch current estimation and a flow transferring identification algorithm based on WAMS to distinguish flow transferring in transient period is presented. The simulation results of 10-generator 39-bus New England system show that the proposed estimation method and the identification algorithm work well.
The lack of quantitative stability analysis software for powersystem is one of the main reasons for losing good chance to implement the emergency control and even finally resulting in the large outage. Recently, the ...
详细信息
The lack of quantitative stability analysis software for powersystem is one of the main reasons for losing good chance to implement the emergency control and even finally resulting in the large outage. Recently, the rapidly developing wide area measurement system (WAMS) gives a new way for quick on-line quantitative transient stability assessment. Starting with the single machine energy function, the relationship between the variation rate of transient unbalance energy and multi-swing stability was analyzed in detail, and the corresponding characteristic of the variation rate of transient energy was proved. Then, a new multi-swing stability assessment criterion based on WAMS was proposed. Numerical simulations were conducted on 6-machine 22-bus system of China electric power research institute to demonstrate the effectiveness of this criterion.
With the development of electric power market, the centralized legacy energy management system (EMS) is hardly adaptive to the polytrope of market environment. Firstly the definitions of agent as well as multi-agent s...
详细信息
Three design schemes of compensation currents for D-STATCOM in delta connection used for unbalanced load compensation are introduced. They are the schemes based on compensation principle of admittance, no zero sequenc...
详细信息
Three design schemes of compensation currents for D-STATCOM in delta connection used for unbalanced load compensation are introduced. They are the schemes based on compensation principle of admittance, no zero sequence component design and an optional design method of maximum minimizing phase current. Comparisons are made considering technical indexes and engineering significance among the proposed three schemes. In serious unbalanced operating conditions, the obvious difference in amplitude among the compensation currents in three phases may lead to one or two phase overloading and the compensation capability is restricted. The optional design makes the compensation currents in three phases to be equal or close to each other as possible as it can, which is helpful to ensure the D-STATCOM having high-usage and desirable compensation effect. Similar performance can be obtained to some extent with the simpler scheme of no zero sequence component design.
Aimed at the necessary on the automatic detection level in unattended substation, a new method which monitoring and diagnosis the high-voltage (HV) power equipment running state based on image processing is put forwar...
详细信息
暂无评论