A new self-shunt excitation control method has been brought in this paper, which is about how to use DC chopper that is composed with full controlled switch device IGBT to regulate exciting voltage. This new method re...
详细信息
Low frequency oscillation (LFO) is harmful to powersystemsecurity and stability. The traditional solutions for LFO are the powersystem stabilizer (PSS) with local or global signal implemented on the excitations. Th...
详细信息
Low frequency oscillation (LFO) is harmful to powersystemsecurity and stability. The traditional solutions for LFO are the powersystem stabilizer (PSS) with local or global signal implemented on the excitations. This paper explores the global governor-side damping controllers for LFO, i.e., controller with input from the wide area measurement system (WAMS). Design strategy of global governor-side damping controller with remote signal from WAMS is proposed, based on the partial state feedback theory. Simulation results in a 4-generator-2-area powersystem show the effectiveness of the proposed global governor-side damping controller.
Distributed generator (DG), with its flexible power generation, environment-friendly advantages has been more widely used in distribution system, which has brought some influence to the traditional distribution networ...
详细信息
When taking emergency control measures to eliminate the overload circuits, it is necessary to ensure the normal lines of powersystem won't overload. Therefore, it's necessary to analyze the security of the no...
详细信息
The removal of overload lines can cause power flow transferring, which may give rise to some transmission lines overload. By analysis of available methods of determining transmission sections with shortcomings, this p...
详细信息
The value setting of the traditional distance protection has become very difficult for the distribution system with distributed generators (DGs) owing to the randomness of the DG output power. This paper proposes a ne...
详细信息
In this paper, a set of five-order dynamic equations of induction motor in d-q coordinates of synchronous generator, which can be interfaced with network equations and generator equations, is derived, meanwhile the fi...
详细信息
In this paper, a set of five-order dynamic equations of induction motor in d-q coordinates of synchronous generator, which can be interfaced with network equations and generator equations, is derived, meanwhile the five-order linearized equations of induction motor as well as the equations of load models containing constant impedance, constant current and constant power are derived too. Utilizing the IEEE first benchmark model, the linearized models containing above-mentioned loads for analysis on subsynchronous resonance (SSR) is established. The influences of above-mentioned static load models and synthetic load model consisting of induction motor and constant impedance on damping characteristics of torsional modes are analyzed. Analysis results show that above-mentioned different load models leads to instability of different damping characteristics of torsional modes, and the analysis results may be over optimistic without regards to load models, and it is impossible to ensure the analysis results always conservative by means of a kind of load model.
Based on the synthetic control of microgrid, a flexible power electronics interface is developed in this paper. Considering distributed generation types and storage devices, different control strategies are adopted in...
详细信息
Digital based data processing and protection and controlsystem along with digital communication networks introduces new structures for substation protection and controlsystems and new methods for intelligent protect...
详细信息
The mechanism of superimposed modal interactions was developed by using the second-order solutions of torques. The frequency-resonant and frequency-beating sup-erimposed modal interactions of two modes were mathematic...
详细信息