This paper puts forward a novel topology of controllable reactor, the structure is based on many small capacity thyristor controlled reactor (TCR) modules and a three-windings transformer connecting to system. The tra...
详细信息
The paper studies a practical project of 2MVA dynamic Voltage Restorer on the basis of transformer-less cascade multilevel topology, it discusses each part working principle of DVR, but also provides a practical volta...
详细信息
This paper presents a new approach for Environmental/Economic transaction planning model of the electricity market. The Environmental/Economic transaction planning problem is formulated as a multi-objective optimal po...
详细信息
Deficiencies of applying the traditional least squares support vector machine (LS-SVM) to time series online prediction were specified. According to the kernel function matrix's property and using the recursive cal...
详细信息
Deficiencies of applying the traditional least squares support vector machine (LS-SVM) to time series online prediction were specified. According to the kernel function matrix's property and using the recursive calculation of block matrix, a new time series online prediction algorithm based on improved LS-SVM was proposed. The historical training results were fully utilized and the computing speed of LS-SVM was enhanced. Then, the improved algorithm was applied to timc series online prediction. Based on the operational data provided by the Northwest power Grid of China, the method was used in the transient stability prediction of electric powersystem. The results show that, compared with the calculation time of the traditional LS-SVM(75 1 600 ms), that of the proposed method in different time windows is 40-60 ms, proposed method is above 0.8. So the improved method is online prediction. and the prediction accuracy(normalized root mean squared error) of the better than the traditional LS-SVM and more suitable for time series online prediction.
Electromagnetic interference (EMI) on secondary de cable in cable tunnel due to a direct lightning strike in substation threatens the safe operation of electronic equipment and system connected to the cable. In order ...
详细信息
Electromagnetic interference (EMI) on secondary de cable in cable tunnel due to a direct lightning strike in substation threatens the safe operation of electronic equipment and system connected to the cable. In order to reduce EMI, the cable shield is generally connected to the grounding grid at both ends. Ground potential difference between two grounding points of the cable shield can be high due to high impedance of the grounding grid at high frequencies. In this paper, we present a hybrid method to analyze this complex system. As a result, both the current flowing in the cable shield and the transverse voltage between the cable core and shield are calculated. Compared with the measured results, the proposed method is demonstrated to be correct and effective.
The dynamic operating characteristics of direct drive permanent magnet synchronous generator (PMSG) were researched. A method of non-linear slope pre-charge for DC-bus voltage is proposed on purpose of protecting powe...
详细信息
This paper focuses on the research on the DC bias due to magnetic storm and HVDC. In the paper, we introduce the DC bias problem of Jiangsu Yang-Huai transmit electric system and Southern power Grids, discuss the harm...
详细信息
The multi-objective fuzzy optimal method based on the fuzzified optimal solutions of single objectives need not list all non-inferior solution sets, which can optimize directly objectives in value area of variables. T...
详细信息
Due to the complexity of powersystems combined with other factors such as increasing susceptibility of equipment, power quality (PQ) is apt to waver. With electricity in growing demand, low PQ is on the rise. the met...
详细信息
Harmonic pollution and reactive power compensation are the important power quality problems. This paper proposes a combined power filter system consisting of the parallel operation of a hybrid active power filter (HAP...
详细信息