Safety Video Display Unit (SVDU) provides the interface between operator and reactor protection system (RPS).SVDU not only displays the signals and parameters which related to safety function but also support the oper...
详细信息
The lower head molten pool model is an important model for the In Vessel Retention (IVR) effectiveness evaluation. It has the characteristics of complex relationship, many input parameters and large uncertainty. The t...
详细信息
This paper studies the exploitation of triple polarization (TP) for multi-user (MU) holographic multiple-input multiple-output surface (HMIMOS) wireless communication systems, aiming at capacity boosting without enlar...
详细信息
Interest in evaluation of reactor response and off-site consequences following beyond design basis accidents has significantly increased after Fukushima. MELCOR is an advanced computational aid that has been widely us...
详细信息
Generally, one of the remarkable characteristics is: compared with the main pipe, the sizes of the auxiliary piping are smaller, which makes the auxiliary piping satisfy the criteria to be decoupled from the main pipi...
详细信息
ISBN:
(纸本)9784888983051
Generally, one of the remarkable characteristics is: compared with the main pipe, the sizes of the auxiliary piping are smaller, which makes the auxiliary piping satisfy the criteria to be decoupled from the main piping. So when the auxiliary pipes connected to the main piping are analyzed, there are two methods: one is that the auxiliary pipe is analyzed connected to the main piping, and the other is that the auxiliary pipe is analyzed not to be connected to the main pipe. Because the response spectrum at the location of the connection of the auxiliary pipes and the main piping is lacked, the previous choice is usually adopted. At present, the main software used for analyzing the stress of the pipes in nuclear power station is PEPS, but when the PEPS is adopted to analyze the small pipes, if the small pipes are analyzed connected to the main pipe, the boundaries of the thermal analysis and those of the seismic analysis are different, so the two kinds of analysis cannot be carried out at the only one model. That is, when the small pipe is analyzed connected to the main piping, two models are needed for thermal analysis and the seismic analysis, and then the results of the thermal analysis and the seismic analysis are distilled separately, and the results are combined according to determinate mode, and then the combined results are evaluated according to the criterion. Consequently, not only is the model complex, but also the combination of the seismic stress and the thermal stress is not convenient in the previous method. In the latter method, the auxiliary pipe is not connected to the main piping, accordingly, not only is the modal simple, but also the combination of the seismic stress and the thermal stress is convenient. The only problem which is needed to be solved is the seismic response spectrum and the displacements, and an approach to solve the problem is presented in the article. A response spectrum calculation method is obtained based on the single oscilla
Water-jet propulsion is a widely applied ship propulsion *** steering control system has an important impact on manoeuvre *** this paper,transfer function model is firstly established on the basis of mechanism analysi...
详细信息
Water-jet propulsion is a widely applied ship propulsion *** steering control system has an important impact on manoeuvre *** this paper,transfer function model is firstly established on the basis of mechanism analysis of water-jet steering ***,by considering the variability of model parameters and input constraints in practical operation,a model predictive controller is designed for steering system ***,model based disturbance observer is employed in an attempt to reject environmental *** performance of the proposed model predictive control (MPC) scheme for a particular steering system is compared with that of conventional proportional integral derivative (PID) control *** results demonstrate that the proposed model predictive controller outperforms conventional PID controller,particularly in robustness,response delay and tracking accuracy.
In this paper, a long-range phase-sensitive optical time-domain reflectometer (φ-OTDR) system is proposed, which is based on the direct detection type φ-OTDR system, combined with the first-order forward Raman distr...
详细信息
In this paper, a long-range phase-sensitive optical time-domain reflectometer (φ-OTDR) system is proposed, which is based on the direct detection type φ-OTDR system, combined with the first-order forward Raman distributed amplification technology and remote pump amplification technology, to achieve 130km vibration monitoring range and 20m spatial resolution. Compared with relay EDFA amplification technology and bidirectional distributed amplification technology, the system eliminates the necessity of a remote power supply, which is of great significance in the monitoring application of long-distance OPGW optical cable.
In this paper, the human factors reliability of standard HUD and adaptive HUD is evaluated by comprehensively using behavioral indicators and physiological indicators. A 3-factor multi-level hybrid experiment (HUD mod...
详细信息
In this paper, the human factors reliability of standard HUD and adaptive HUD is evaluated by comprehensively using behavioral indicators and physiological indicators. A 3-factor multi-level hybrid experiment (HUD mode mission environment repetition times) was used to explore the load difference and performance difference between adaptive HUD and traditional HUD in different flight stages and different flight duration during flight. The results show that compared with the traditional HUD, the adaptive HUD system can significantly reduce the mental load of pilots in the takeoff and approach landing phases, and in the case of long-term flight, the adaptive HUD system will not cause additional burden to the subjects. keywords: HUD, human reliability, ET, ECG, EEG
暂无评论