An agile and coordinated voltage control method is proposed to deal with the power system reactive power and voltage operation with large scale wind power integration. In the provincial control center, the agile volta...
详细信息
Nowadays, the concentrating solar power (CSP) plant with thermal storage is a new way to utilize solar power. By making full use of large-capacity CSP devices, the CSP system is able to translate the solar power absor...
详细信息
The development of high voltage direct current (HVDC) grid is an effective approach to implement the large-scale long-distance power transmission, the large-scale renewable energy integration and accommodation, and th...
详细信息
Inter-turn short circuit of field windings is a common electrical fault of *** is an important method of investigating the fault and providing data support for fault ***,huge numbers of pole pairs and damper loops in ...
详细信息
Inter-turn short circuit of field windings is a common electrical fault of *** is an important method of investigating the fault and providing data support for fault ***,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering *** deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment *** the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the *** calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original ***,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault ***,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is *** result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.
Very-fast transient overvoltage (VFTO)-related problems are raising growing concerns in China with the development of ultra-high voltage. The practice of fitting ferrite rings on gas-insulated switchgear busbars for V...
详细信息
The development of UHV transmission technology brings longer transmission distance, higher towers and more complicated terrain along the transmission lines, which make the shunt performance of transmission line under ...
详细信息
ISBN:
(纸本)9781479935451
The development of UHV transmission technology brings longer transmission distance, higher towers and more complicated terrain along the transmission lines, which make the shunt performance of transmission line under lightning stroke more diversiform compared to conventional ones. This paper discusses the effects of factors, such as lightning current waveform, footing resistance, transmission line span etc., on the shunt coefficient of UHV DC transmission lines, which is of great significance for setting out lightning-proof measures as well as the location of lightning stroke point. It is referred that lightning current waveform especially its front time as well as tower footing resistance plays a significant role in determine of the tower shunt coefficient under lightning stroke. As the results indicates, the shunt coefficient of ground wire gets larger as the footing resistance increases while it decreases first and then increases as the front time of the lightning current waveform increases. The shunt coefficient of tower is just the opposite.
A broadband RF energy harvesting system over a frequency range of 900MHz-3GHz has been designed and tested. Some detailed issues of RF design have been studied and tested to improve the efficiency of the rectifier. Te...
详细信息
A broadband RF energy harvesting system over a frequency range of 900MHz-3GHz has been designed and tested. Some detailed issues of RF design have been studied and tested to improve the efficiency of the rectifier. Test results show that as low as -20dBm RF power can be harvested by this system. The series and parallel connections of two RF energy harvesting systems have also been studied, compared with the single system.
As the traditional centralized network modeling for energy management system (EMS) in control center is error prone, heavily reliant on maintenance, and lacking in self-healing ability while unable to satisfy the need...
详细信息
Low voltage distribution network usually operates under three-phase unbalanced conditions. And the distributed generators (DGs), integrated with distribution network, show different behaviors under different control s...
详细信息
In order to avoid irrational reactive power flow and voltage distribution, the coordinated voltage controlsystem integrated for regional, provincial and prefectural control centers in China Southern power Grid is prop...