Due to the power electronic devices in doubly fed induction generators (DFIG), it is very time consuming to simulate the electromagnetic transients of DFIG using its detailed model. Thus it is necessary to have approp...
详细信息
ISBN:
(纸本)9781629936017
Due to the power electronic devices in doubly fed induction generators (DFIG), it is very time consuming to simulate the electromagnetic transients of DFIG using its detailed model. Thus it is necessary to have appropriately simplified model of DFIG that maintains desirable accuracy. In this paper, the piecewise averaged model of PWM converters is introduced and applied to the modelling of DFIG. The proposed model divides the simulation time interval into switching periods and recalculates the averaged state equations of PWM converters in each switching cycle. In addition, a predictorcorrector based EMTP algorithm is designed to iteratively solve the model. Instead of treating switching events at the time points when they happen, the new algorithm solves all the switching instants in a switching cycle at the same time, which avoids frequency modification of the system conductance matrix and speeds up EMT simulations of DFIG. simulation results of a single-machine infinity bus system with a DFIG show that the proposed model and algorithm can achieve satisfactory accuracy and efficiency.
power flow exhibits uncertainty when power injections randomly fluctuate. The variables of power flow problem are correlated through the constraints set forth by power flow equations. Affine arithmetic can effectively...
详细信息
The analysis and simulation of power system are becoming more and more challenging as the complexity of system topology and components has been increased. In this paper, a hybrid parallel algorithm is proposed for the...
详细信息
The analysis and simulation of power system are becoming more and more challenging as the complexity of system topology and components has been increased. In this paper, a hybrid parallel algorithm is proposed for the real-time electromagnetic transient simulation (EMTS) of integrated powersystems containing multiphase machines. The proposed algorithm is com- posed of a novel network partition method called component level parallelization and the Multi-Area Thevenin Equivalent (MATE) method, which extends the flexibility of the network partition in parallel simulation. Moreover, several methods are developed to enhance the efficiency of the communication and computation. powersystems with up to 410 single-phase elec- trical nodes and 336 switches are simulated in a time step of 50 ~ts to validate the proposed algorithm.
The smart grid is attracting more and more attention in electrical engineering for its promising ***,huge challenges also exist in the implementations of the smart grid,such as high penetration of renewable energy res...
详细信息
The smart grid is attracting more and more attention in electrical engineering for its promising ***,huge challenges also exist in the implementations of the smart grid,such as high penetration of renewable energy resources,low carbon electricity and cyber-physical security,*** this paper,the latest progress of some research focuses and advance technologies in the development of smart grid is reviewed.
To coordinately consider the economy and security of the system during reactive voltage control, a multi-objective reactive power optimization model is proposed. Apart from the conventional economic objective, the new...
详细信息
A two-level distributed state estimation method for substation-dispatch center is proposed. After zero impedance three-phase state estimation based on KCL has been applied in substation, up load ripe data are treated ...
详细信息
A fast electric field integral in time domain using the uneven discretization and the implicit scheme is proposed to calculate the switching electromagnetic transient at a substation. The switching transient currents ...
详细信息
Formulation of day-ahead operation schedule for large-scale power grid requires security validation, including static security, dynamic and transient stability. It is an important and basic task for day-ahead security...
详细信息
Shielding failure is one of key problems of UHV transmission lines. Considering the high operating voltage and high tower of UHV transmission lines, the inception criterion of upward leader is proposed in this paper. ...
详细信息
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durat...
详细信息
ISBN:
(纸本)9781849196208
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durations are controlled by the tripping time of overcurrent relay in power collection lines based on the sags' magnitude. The specification of the LVRT capacity of wind generator is introduced into the operation characteristics of the relay in power collection lines. The evaluation model of equivalent LVRT capacity to overcurrent protection is proposed in paper, and the equivalent LVRT capacities from zone I and zone II relay are quantified. Improvement measures are also proposed.
暂无评论