High-efficient noble-metal-free photocatalyst is vital to realize high H 2 evolution. In consideration of this, we design a [email protected] reinforced concrete structure derived from nickel foam (NF) via a simp...
High-efficient noble-metal-free photocatalyst is vital to realize high H 2 evolution. In consideration of this, we design a [email protected] reinforced concrete structure derived from nickel foam (NF) via a simple one-pot oil bath strategy. The whole preparation process is started with the growth of NiS rods on NF. Subsequently, NiS rods are encased in CdS gradually under oil both conditions. After the combination of NiS rods and CdS, the photoelectrical properties of primeval CdS are greatly optimized, e.g. , photoelectric responsiveness, impedance and light absorption capacity. Moreover, the H 2 evolution rate of [email protected] is increased significantly from 2706 to 40601 μmol g −1 h −1 under visible-light irradiation (λ > 420 nm), which is about 15 times higher than that of pure CdS, thereby confirming the excellent synergistic effect between NiS rods and CdS. Additionally, the photocatalytic performance of [email protected] was stronger than that of CdS/NiS-NPs (6726 μmol g −1 h −1 ) and CdS-NPs/NiS (1639 μmol g −1 h −1 ), highlighting the advantages of CdS (prepared using oil bath treatment) and NiS rods (originated from NF growth). Lastly, according to experiment data and DFT calculation results, a viable mechanism for [email protected] is tentatively proposed.
This paper presents a comprehensive analysis of the water vaporization in a hot water boiler system. The Computational Fluid Dynamics (CFD) technology was adopted to simulate the transient water evaporation in the boi...
This paper presents a comprehensive analysis of the water vaporization in a hot water boiler system. The Computational Fluid Dynamics (CFD) technology was adopted to simulate the transient water evaporation in the boiler termed as DZL14-1.25/115/70-AⅡ under the assumption of extreme conditions such as the water pump failure. The results indicated that the average pressure in the pipeline increased from 0.57Mpa to 0.66Mpa (the setting pressure of the safety valve) within 1050s. The pressure increased rapidly with the time increase. The average temperature of hot water changed linearly with time, and the internal thermal deviation of the hot water pipeline in the boiler decreased with time. The internal vaporization phenomenon of the hot water boiler became significant under the extreme condition. The steam flowed upward and accumulated in the upper part of the boiler shell. At 1050s, the vapor volume fraction in the hot boiler was 1.05%, which indicated that the safety valve above the stream shell need to be opened in time after 1050s to ensure the safety of the boiler.
Rate coefficients of H-atom abstraction and addition reactions of 3-hexene by the hydroxyl radical (H) were determined using canonical variational transition-state theory, with potential energy surface evaluated at th...
详细信息
The power grid peaking capacity is insufficient due to the increasing installed capacity of renewable power. Moreover, it is also restricted by the operation mode of combined heat and power units (CHPs), the minimum e...
The power grid peaking capacity is insufficient due to the increasing installed capacity of renewable power. Moreover, it is also restricted by the operation mode of combined heat and power units (CHPs), the minimum electricity loads of which are determined by the heat load. It is significant to study the heat-electricity decoupling technologies for CHPs. Therefore, the low-pressure steam turbine renovation technology is studied in this paper with a 300MW unit as reference case. Results show that the minimum electric load rate and the coal consumption are decreased, and the heat-electricity ratio is increased significantly for CHP with low-pressure steam turbine renovation. When the heat load is 1200 GJ/h, the minimum electric load rate and coal consumption with low-pressure steam turbine renovation can be reduced by 32.4 and 30.9 % respectively. The heat-electricity ratio can be increased by 68.8 % after renovation of low-pressure steam turbine.
An experimental study on flame front evolution and self-acceleration of hydrogen spherically expending flames was conducted on a constant volume combustion chamber over a wide range of Lewis number at elevated pressur...
详细信息
A highly-integrated experimental system for the plasma decomposition of fuels was *** were conducted in a flow reactor at atmospheric pressure and confirmed that n-decane could be cracked by large-gap dielectric barri...
详细信息
A highly-integrated experimental system for the plasma decomposition of fuels was *** were conducted in a flow reactor at atmospheric pressure and confirmed that n-decane could be cracked by large-gap dielectric barrier discharge under the excitation of a microsecond-pulse power supply. Alkanes and olefins with a C atom number that is smaller than10 as well as hydrogen were found in the cracked products of n-decane(n-C10 H22). The combination of preheating and plasma decomposition had strong selectivity for olefins. Under strong discharge conditions, small molecule olefins were found in the products. Moreover, there was a general tendency that small molecule olefins gradually accounted for higher percentage of products at higher temperature and discharge frequency.
In order to expand the study on flow instability of supercritical circulating fluidized bed(CFB) boiler,a new numerical computational model considering the heat storage of the tube wall metal was presented in this ***...
详细信息
In order to expand the study on flow instability of supercritical circulating fluidized bed(CFB) boiler,a new numerical computational model considering the heat storage of the tube wall metal was presented in this *** lumped parameter method was proposed for wall temperature calculation and the single channel model was adopted for the analysis of flow *** on the time-domain method,a new numerical computational program suitable for the analysis of flow instability in the water wall of supercritical CFB boiler with annular furnace was *** verify the code,calculation results were respectively compared with data of commercial *** to the comparisons,the new code was proved to be reasonable and accurate for practical engineering application in analysis of flow *** on the new program,the flow instability of supercritical CFB boiler with annular furnace was simulated by time-domain *** 1.2 times heat load disturbance was applied on the loop,results showed that the inlet flow rate,outlet flow rate and wall temperature fluctuated with time eventually remained at constant values,suggesting that the hydrodynamic flow was *** results also showed that in the case of considering the heat storage,the flow in the water wall is easier to return to stable state than without considering heat storage.
Motivated by reducing the uncertainties in coolability analysis of a debris bed, this paper proposed a modified model for the pressure drops of two phase flow through packed beds with coarse particles based on the exp...
详细信息
The experimental monitoring system of pressurized-liquid-screen bed was designed and set in this paper. The flow characteristics were studied especially the analysis of differential pressure pulse characteristics and ...
详细信息