Summary form only given. Between the output electrodes of a 500 kV/400 kA/100 ns pulsed-power generator, two Al wires each with diameter of 10-100 mum crossing and touching at a single point constitute an "x"...
详细信息
Summary form only given. Between the output electrodes of a 500 kV/400 kA/100 ns pulsed-power generator, two Al wires each with diameter of 10-100 mum crossing and touching at a single point constitute an "x" shape load. The cross position explodes first and then pinches axially to form so-called X-pinch plasma as current is delivered to the "x" wires. In order to analyze the energy spectra of ion beams emitted from x-pinch, a compact Thomson spectrometer was designed and constructed. It consists of an entrance window, a pair of small permanent magnets, an exit pinhole, and a high sensitive nuclear track detector of CR-39 plastic plate. Ion beams experience deflections in the electromagnetic field, and then hit the target (CR-39 plastic) at different positions and form craters, then the craters form different parabolic track with different ratio of ion mass to ion charge. By counting the track density of the parabolas, charge state resolved energy spectra of ion beams were obtained
In the AC adjusting speed system, the significant current impulse frequently occurs in the starting process while the output torque is sufficient. This would damage the power electronics device, cause the unbalance of...
详细信息
In the AC adjusting speed system, the significant current impulse frequently occurs in the starting process while the output torque is sufficient. This would damage the power electronics device, cause the unbalance of neutral point in three-level NPC topology, and deteriorate the starting performance. In this paper, a DC pre-excitation strategy, which limits the starting current and enhances the electromagnetic torque via establishing the flux linkage before starting process, is proposed to the three-level inverter under analysis on the mechanism of the above large current. The relevant experiments present its eminent effect on the 380 V/160 kW inverter-motor system. Also this paper discuss the feasibility of its application in high voltage high power inverter.
A software-based system was developed for fault detection and diagnosis (FDD) of controlsystems in typical thermal power plants. For the large-scale industrial processes as thermal power plants, a three-level configu...
详细信息
A software-based system was developed for fault detection and diagnosis (FDD) of controlsystems in typical thermal power plants. For the large-scale industrial processes as thermal power plants, a three-level configuration to build a realtime FDD system is proposed. This configuration includes the component level, loop level and system level. Developed algorithms for each level and systematic approaches and steps to implement the overall diagnostic system are discussed. The developed system has been applied to a real-world thermal power plant to monitor its main controlsystems
Two axially-laminated Glued Axially-Laminated Synchronous Reluctance Permanent Magnetic (SR-PM) motors are designed and tested. Compared to general Axially-Laminated Synchronous Reluctance (SR) motors, the steel brack...
详细信息
Computer control and monitoring system (CCMS) is quite important for high power converters (HPCs) operation. This paper presents a novel CCMS, which integrates a database management system (DBMS) into the monitoring s...
详细信息
ISBN:
(纸本)7506274078
Computer control and monitoring system (CCMS) is quite important for high power converters (HPCs) operation. This paper presents a novel CCMS, which integrates a database management system (DBMS) into the monitoring software to get the beneficial features such as simple configuration and compact structure. In its communication system, an advanced optical fiber communication (OFC) technology is applied and priority-based communications is proposed to improve the reliability and the real time of the communications. Furthermore, a friendly standard Windows human-machine interface (HMI) is provided. The reliability and performance of the system are verified by system tests and practical operations.
In view of the impossibility of current measurement in actual grounding plane in power electronic equipment, an equivalent circuit model is set up in this paper using the partial element equivalent circuit (PEEC) meth...
详细信息
ISBN:
(纸本)7506274078
In view of the impossibility of current measurement in actual grounding plane in power electronic equipment, an equivalent circuit model is set up in this paper using the partial element equivalent circuit (PEEC) method to simulate and calculate current distribution in grounding plane. The inductance parameters calculated are fairly coincident with experiment results, and some conclusions of current distribution are summarized. It is shown that the equivalent circuit model using PEEC method presented in this paper is a feasible and promising way to model and calculate current distribution in grounding plane.
This paper presents an accurate flux observer used in distributed multi-processor (DMP) adjustable speed drive systems. The stator flux linkage is estimated with a full-order observer, while the rotor speed is identif...
详细信息
ISBN:
(纸本)7506274078
This paper presents an accurate flux observer used in distributed multi-processor (DMP) adjustable speed drive systems. The stator flux linkage is estimated with a full-order observer, while the rotor speed is identified by using Lyapunov theorem. In order to improve the system performance in a wide speed range, the stator resistance is estimated simultaneously. In this paper, the structure of the DMP system, the principle of the full-order observer and the method for identifying the rotor speed and state resistance are all described in details. Relevant simulation results based on MATLAB/SIMULINK are given to prove the performance of the method. Experiments of a real system also verify the feasibility of this scheme.
To simplify the calculation of winding bar temperature for the condition monitoring of the water cooling stator of Three-Gorge Hydro-Generator, this paper calculates three of two-dimension thermal fields. Using the th...
详细信息
ISBN:
(纸本)7506274078
To simplify the calculation of winding bar temperature for the condition monitoring of the water cooling stator of Three-Gorge Hydro-Generator, this paper calculates three of two-dimension thermal fields. Using the three fields simulates the different section along the axial direction of the generator. The total amount of heat taken away by water can be calculated by weighting the result of three fields on the total axial length of them. Four groups of thermal-fields with different outlet-water temperature are calculated by using ANSYS multi-physical software. The calculation results of temperature of measurement-point between up-layer and down-layer bars in stator are partly supported by the measurement data. And the relatively error between the heat taken by cooling-water and the heat generated by the stator bar is always less than 5%.
In order to detect the abnormal temperature of large oil-Immersed power transformer earlier, this paper presents a new prediction-model of surface-temperature for the transformer to predict the normal surf ace-tempera...
详细信息
ISBN:
(纸本)7506274078
In order to detect the abnormal temperature of large oil-Immersed power transformer earlier, this paper presents a new prediction-model of surface-temperature for the transformer to predict the normal surf ace-temperature. And to compare the difference between the predicted value and the measured value can judge If the condition of the transformer Is fit to operate. The model parameters are estimated from the field data by using the Partial-Least-Square method, which overcomes the instability of results estimated by using the traditional Least-Square method. Furthermore, the appropriate amount of data for the parameter estimation was decided according to the principle of Heat Transfer and the characteristics of the predicted deviation, such as mean, variance and normal distribution. The prediction model is verified from the accuracy of results predicted with one year of field data.
暂无评论