The adaptive immune algorithm (AIA) developed from immune algorithm (IA), owns faster computation speed and better convergence than that of GA and other stochastic type algorithms, due to its characteristic of having ...
详细信息
A MicroGrid can increase the reliability of energy supplies by disconnecting from the grid in the case of network faults or reduced power quality. The techniques that have been investigated to control MicroGrids in bo...
详细信息
An interface powercontrol strategy based on power flow tracing and generator re-dispatch is presented. power flow on the interface is firstly traced backward to the sending-end system to locate the generators to be a...
详细信息
Adaptive Immune Algorithm based data mining (AIA-Data Mining) is presented for fault diagnosis of power transformer. The information entropy is used for the production of the initial population, which leads to converg...
详细信息
At present, the load modeling is still one of the difficult problems in powersystem. In this paper, a new method is presented which uses wide-area measurements and support vector machine (SVM) for load modeling. Base...
详细信息
ANN-based data-mining techniques are introduced to detect the most influential variables causing the mismatch of super-heater outlet steam temperatures. The strategies are: (1) Rough set selection: the rough variables...
详细信息
UHV long transmission line takes on distinct characteristics of distributed parameters, and it has great capacitive currents. Traditional phase segregated current differential protection is severely influenced by dist...
详细信息
This paper presents a novel combined algorithm based on particle swarm optimization (PSO) and simulated annealing algorithm(SA) for powersystem reactive optimization. According to the characteristics of PSO and SA, t...
详细信息
In this paper, the deterioration investigation was carried on an ex-serviced 110 kV cross-linked polyethylene (XLPE) cable. XLPE sheets sliced from the cable insulation were taken as the test samples and the residual ...
详细信息
In this paper, the deterioration investigation was carried on an ex-serviced 110 kV cross-linked polyethylene (XLPE) cable. XLPE sheets sliced from the cable insulation were taken as the test samples and the residual charge method was used as the diagnostic method. Two aluminum foils attached on the both sides of sample surface made the electrode constitution, between which the voltage was applied and the current was simultaneously measured. The residual charge was calculated to estimate the degree of the degradation. Additionally, Tan¿ test was carried out to assist the evaluation of cable degradation. Obtained results show that the degradation degree within the insulation varies with the changes of the position. The XLPE sheets near the outer semicon and the conductor aged more severely than that of the middle part. Meanwhile, the cable was anatomized and it was found that the water blocking layer had mildewed and the color of the outer part insulation turned into black.