To research the influence of multi-phase winding to generators and calculate the losses in solid rotors, the stator mint of a 12-phase asynchronous generator have been well analyzed and finite element method by ANSYS ...
详细信息
ISBN:
(纸本)7506274078
To research the influence of multi-phase winding to generators and calculate the losses in solid rotors, the stator mint of a 12-phase asynchronous generator have been well analyzed and finite element method by ANSYS software has been applied to get the accurate losses in the rotor through both harmonic and transient 2-D analysis. The relationship between stator harmonic current and stator harmonic mint has been deduced and proved through ANSYS software to some extent, and rotor losses produced by both stator fundamental current and stator total current have also been obtained and compared. The results show that 12-phase stator winding with appropriate short pitch can effectively eliminate or reduce many mmf produced by stator fundamental and harmonic current and rotor losses are mainly produced by stator fundamental current.
The structure of distribution network becomes more and more complex. In order to ensure the safety and stable operation of the system, it is necessary to obtain the current network structure in real time. In order to ...
详细信息
As an important component of a wind turbine drive chain, the high failure rate of the gearbox can have a serious impact on the operation of wind turbine units. The fault diagnosis of the gearbox is therefore important...
详细信息
As a key indicator of whether the photovoltaic power generation system is friendly to the grid, low voltage ride-through is related to the safe and stable operation of the grid. In order to further enhance the low vol...
详细信息
In order to study the reasonable capacity of power grid to absorb wind power, a new calculation method is proposed for the combined system of thermal power and wind power. In this paper, the probability and statistics...
详细信息
Computer control and monitoring system (CCMS) is quite important for high power converters (HPCs) operation. This paper presents a novel CCMS, which integrates a database management system (DBMS) into the monitoring s...
详细信息
ISBN:
(纸本)7506274078
Computer control and monitoring system (CCMS) is quite important for high power converters (HPCs) operation. This paper presents a novel CCMS, which integrates a database management system (DBMS) into the monitoring software to get the beneficial features such as simple configuration and compact structure. In its communication system, an advanced optical fiber communication (OFC) technology is applied and priority-based communications is proposed to improve the reliability and the real time of the communications. Furthermore, a friendly standard Windows human-machine interface (HMI) is provided. The reliability and performance of the system are verified by system tests and practical operations.
This paper proposes a hierarchical control scheme for parallel grid-connected PV inverters with a common dc bus. Droop control and group coordination are implemented to achieve equal power sharing between inverters as...
详细信息
ISBN:
(纸本)9781849197588
This paper proposes a hierarchical control scheme for parallel grid-connected PV inverters with a common dc bus. Droop control and group coordination are implemented to achieve equal power sharing between inverters as well as zero steady-state error for dc voltage regulation. The implementation is specifically designed for distributed control to promote modularization and system reliability. Experimental results have verified that the proposed scheme is effective.
The cracks emerged in a fossil-fired power plant in China in 2008 and several similar crack accidents had been detected in nuclear turbines in USA before. The possible causes of the cracks are analyzed in previous stu...
详细信息
ISBN:
(纸本)9784883254194
The cracks emerged in a fossil-fired power plant in China in 2008 and several similar crack accidents had been detected in nuclear turbines in USA before. The possible causes of the cracks are analyzed in previous study while the torsional vibration is one of the most significant factors. The paper analyzes the impact of torsional vibration using the practical running data in some turbine generator unit. Based on the transient response analysis under emulational subsynchronous oscillation model simplified from the practical network, the torques acted on the coupling section are analyzed. Then the stress and strain field is calculated for local dangerous point search in Zone of Vulnerability (ZoV) and the fatigue damage criterion determination. Manson-Coffin equation is used to ascertain whether it is high-cycle fatigue or low-cycle fatigue and the fatigue data from standard test specimen is used. The method using local stress and strain analysis as well as fatigue damage cumulation study may establish a novel way to diagnose the crack in an early stage.
In order to study the electromagnetic coupling law of one typical metal body, electromagnetic simulation software FEKO is utilized to set up the typical metal body model. With the increase of the simulation frequency,...
详细信息
A large number of text and reports about the power equipment are generated in power system, which consist of implicit information of operation condition and insulation status. With the development of convolutional neu...
详细信息
暂无评论