Finding the ground states of Sherrington-Kirkpatrick (SK) spin glass, the mean-filed spin glass model with strongly connected variables, is well known as a typical NP-hard problem. This paper presents a modified extre...
详细信息
Hysteretic optimization (HO) is a recently proposed optimization method based on the well-known demagnetization process of magnetic materials in physics. In this study, we apply HO to the protein folding problem, an a...
详细信息
Based on the state-of-the-art technologies of the Internet of Things (IOT) and Radio Frequency Identifier (RFID) this paper introduces the concepts of IOT/RFID and investigates its open research opportunity and potent...
详细信息
Much of the previous work in the protein field focused on the 2D protein folding due to its simplicity but ignored the 3D protein folding problem. In this paper, based on the work of 2D protein folding problem by prim...
详细信息
Water-soluble quantum dots (QDs) are effective reagents,have minimal toxicity,are compatible with biological system,and have shown potential as tumor diagnostic ***,little is known about their biological behaviors in ...
详细信息
Water-soluble quantum dots (QDs) are effective reagents,have minimal toxicity,are compatible with biological system,and have shown potential as tumor diagnostic ***,little is known about their biological behaviors in *** recent in vivo studies concentrated on the biokinetics of cadmium telluride (CdTe) *** ICR mice were intravenously given a single dose (2.5 μmol/kg body weight) of water-soluble cadmium-telluride (CdTe) QDs (the QDs are approximately 4 nm in diameter and have maximal emission at 630 nm).Inductively coupled plasma mass spectrometry (ICP-MS) was used to measure the kinetic action of 111Cd and 125Te for 7 *** plasma kinetics of cadmium (Cd) and tellurium (Te) followed a two-compartment model,in which Te exhibited lower volume of distribution (107.41 ± 9.75 ml/kg vs.127.25 ± 5.65 ml/kg),AUC (15.28 ± 0.89 μg/ml?h vs.18.73 ± 2.29μg/ml?h),rapid elimination half-life (21.55 ± 0.24 h vs.49.28 ± 2.79 h),and clearance (10.38 ± 0.80 ml?kg-1?h-1 vs.14.81 ± 1.90 ml/kg?h),and a slower distribution half-life (7.17 ± 0.06 h vs.6.01 ± 0.58 h) compared to the *** to its relatively transient fate in the plasma,high levels of Cd persisted in the liver and kidneys throughout the experimental *** the kidneys,the tissue concentration showed an increase after *** with Cd,the overall half-life of Te in the body was very ***,Te accumulated primarily in the spleen,followed by liver and *** different plasma kinetics and distribution patterns of Cd and Te imply that CdTe QDs have been part of the degradation or aggregation in vivo.
In this paper dynamic power shaping control is applied to a continuous fermentation process which is a benchmark problem in the nonlinear process systems. In contrast with other techniques, dynamic power shaping contr...
详细信息
The paper considers the problem of tracking control of a class of nonlinear systems with unknown periodic time-varying parameters via dynamic output feedback. Both matched disturbances and unmatched disturbances are c...
详细信息
Many algorithms have been proposed for mining fuzzy association rules in static datasets with quantitative attributes. However, there is few study on mining fuzzy association rules in data streams. This paper presents...
详细信息
Recursive subspace identification methods have been an active area of research in recent years. In this paper, a recursive version of a closed-loop subspace method is proposed for on-line system modeling. The algorith...
详细信息
This paper is concerned with the control performance assessment based on the multivariable generalized minimum variance *** explicit expression for the feedback controller-invariant(the generalized minimum variance)te...
详细信息
This paper is concerned with the control performance assessment based on the multivariable generalized minimum variance *** explicit expression for the feedback controller-invariant(the generalized minimum variance)term of the multivariable control system is obtained,which is used as a standard benchmark for the assessment of the control performance for multi input multi output(MIMO)*** proposed approach is based on the multivariable minimum variance *** comparison with the minimum variance benchmark, the developed method is more reasonable and practical for the control performance assessment of multivariable *** approach is illustrated by a simulation example and an industrial application.