Commutation failure (CF) is one of the major concerns in high-voltage direct current (HVDC) transmission system. Of many methods to mitigate CF, advancing firing angle is preferred one since it can be easily implement...
详细信息
With widely utilization of distributed generations (DGs) and demand response (DR), the active distribution network (ADN) becomes a more proactive and strategic consumer in electricity markets to procure its energy nee...
详细信息
To protect the environment and lower carbon dioxide emissions, conventional fossil-fuel generators tend to be replaced by renewable generation. The volatile and uncertain renewable generation, as well as the reduced p...
详细信息
By replacing multiple two-winding transformers with a multi-winding transformer (MWT) in the isolated DC-DC converter, it can reduce the volume and increase the power density. Due to magnetic coupling in MWT, power wi...
详细信息
Dielectric barrier discharge (DBD) between two cylindrical glass containers with salt water generated by a nanosecond repetitively pulsed power generator is reported. The electrical parameters, luminous images and s...
详细信息
Dielectric barrier discharge (DBD) between two cylindrical glass containers with salt water generated by a nanosecond repetitively pulsed power generator is reported. The electrical parameters, luminous images and spectrum diagnosis are presented. It is shown that the DBD possesses a large discharge current and an intense optical emission from the nitrogen second positive system below 400 nm. The gas temperature remains very close to room temperature regardless of pulse polarity. Luminous photographs with a short exposure time down to 2 ns indicate that no filament is observed and the discharge is homogeneous.
Instantaneous energy balancing plays an important role in power electronics conversion. The unbalance of electromagnetic energy not only debases the system performance but also decreases the reliability and efficiency...
详细信息
Traveling wave method has been proved to be effective in fault line selection of power distribution system with the neutral non-effectively grounded. However, it can be easily disturbed by non-faulty traveling wave wh...
详细信息
DC-line fault recovery sequence (DFRS) is widely implemented in LCC-HVDC system to realize fast recovery in case of temporary fault. When permanent fault occurs, restart still happens several times as preset, resultin...
详细信息
The communication protocol is important for applying adjustable speed drive (ASD) systems to an industry network. This paper proposes a novel scheme of communication system for the ASD system based on Modbus protocol....
详细信息
Dielectric barrier discharge (DBD) excitated by pulsed power is a promising method for producing nonthermal plasma at atmospheric pressure. Discharge characteristic in a DBD with salt water as electrodes by a home-m...
详细信息
Dielectric barrier discharge (DBD) excitated by pulsed power is a promising method for producing nonthermal plasma at atmospheric pressure. Discharge characteristic in a DBD with salt water as electrodes by a home-made unipolar nanosecond-pulse power source is presented in this paper. The generator is capable of providing repetitive pulses with the voltage up to 30 kV and duration of 70 ns at a 300 Ω resistive load. Applied voltage and discharge current are measured under various experimental conditions. The DBD created between two liquid electrodes shows that the discharge is homogeneous and diffuse in the whole discharge regime, Spectra diagnosis is conducted by an optical emission spectroscopy. The air plasma has strong emission from nitrogen species below 400 nm, notably the nitrogen second positive system.