The utilization of solar heat and waste heat in order to energize absorption chillers is an important issue for increasing the energy efficiency of cooling machines. A compact pump-free LiBr absorption refrigeration s...
详细信息
ISBN:
(纸本)1563479028
The utilization of solar heat and waste heat in order to energize absorption chillers is an important issue for increasing the energy efficiency of cooling machines. A compact pump-free LiBr absorption refrigeration system (without the generator-pump, the evaporator-pump and the absorber-pump) driven by solar energy is designed and reconstructed. The required minimum driving temperature of the heat source is only 68°C compared to above 100°C in traditional absorption refrigeration systems. This paper aims to present the effects of various running parameters on the heat transfer performance of a solar refrigeration system, and typical experimental data. The phase change heat transfer is intensified in both the lunate channel of the thermosiphon elevation tube and the second generator. In this way, the two-phase solution is elevated continuously without pumps with a low driving temperature. The structure of the overflow-type spray system is optimized to make the aqueous solution of LiBr be absorbed and to make the condensate be evaporated in a once-through spray. Therefore, the aqueous solution in the refrigeration system can be in steady continuous absorption and evaporation without the absorber pump and the evaporator pump. In a cross-flow horizontal falling film heat exchanger, the staggered coil is wrapped with the mesh screen to hold up more liquid film. The performance of the heat and mass transfer is improved due to an increase in the wet ratio of the surface. Based on the heat and mass transfer theory of falling film absorption, an experimental study is carried out to analyze the performance of the refrigeration system. An experimental investigation is undertaken to characterize the effects of the absorption pressure, the inlet temperature of the solution, and the inlet temperature of the cooling water on the heat and mass transfer in the absorption process. The implications of the data are discussed in detail.
In bubbly two‐phase flow, the gas phase and liquid phase have different flow fields. The mathematical expression for the motion of a small bubble at low Re number has been already established, the liquid velocity alo...
In bubbly two‐phase flow, the gas phase and liquid phase have different flow fields. The mathematical expression for the motion of a small bubble at low Re number has been already established, the liquid velocity along the trajectory of the bubble is calculated inversely by using the motion equation. Whole field liquid flow structure has also estimated using a spatial and/or temporal interpolation method. This paper proposes an algorithm for estimating the liquid phase flow field based on measurement data on bubble data on bubble motion. The applicability of the algorithm is examined with Taylor‐Green vortex flow as an analytical test case. Meanwhile, The result, based on the theory, has been applied to reconstruct liquid phase velocity field by using the data of bubble velocity in an aeration tank.
Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4 × 4 ( columns × rows) finned-tube heat exchanger w...
详细信息
Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4 × 4 ( columns × rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50. 2 m/s, the heal transfer rate ranged from 21.8 to47. 1 kW, and the air temperatures increase ranged from 10. 9 to 19. 8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlations. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are DrODosed based on the experimental results.
This work used artificial neural network(ANN)to predict the heat transfer rates of shell-and-tube heatexchangers with segmental baffles or continuous helical baffles,based on limited experimental *** BackPropagation (...
详细信息
This work used artificial neural network(ANN)to predict the heat transfer rates of shell-and-tube heatexchangers with segmental baffles or continuous helical baffles,based on limited experimental *** BackPropagation (BP) algorithm was used in training the *** network configurations were *** deviation between the predicted results and experimental data was less than 2%.Comparison withcorrelation for prediction shows ANN *** is recommended that ANN can be easily used to predict theperformances of thermal systems in engineering applications,especially to model heat exchangers for heattransfer analysis.
This article presents a theoretical investigation on the steady-state natural circulation characteristics of a new type of pressurized water reactor. Through numerically solving the one-dimensional steady-state single...
详细信息
This article presents a theoretical investigation on the steady-state natural circulation characteristics of a new type of pressurized water reactor. Through numerically solving the one-dimensional steady-state single-phase conservative equations for the primary circuit and the steady-state two-phase drift-flux conservative equations for the secondary side of the steam generator, the natural circulation characteristics were studied. On the basis of the pre- liminary calculation analysis, it was found that natural circulation mass flow rate was proportional to the exponential function of the power and that the value of the exponent is related to the operating conditions of the secondary side of the steam generator. The higher the outlet pressure of the secondary side of the steam generator, the higher the pri- mary natural circulation mass flow rate. The larger height difference between the core center and the steam generator center is favorable for the heat removal capacity of the natural circulation.
Aeration plays an important role in the treatment of activated sludge. The aeration performance is deeply affected by the movement law of bubble liquid flow in aeration tank. In order to discuss the influence of gas‐...
Aeration plays an important role in the treatment of activated sludge. The aeration performance is deeply affected by the movement law of bubble liquid flow in aeration tank. In order to discuss the influence of gas‐phase, liquid‐phase motions in an aeration tank on the sewage disposal, three kinds of boundaries and initial conditions were applied in the experiment to study the law of two‐phase flow. A developed two‐equation turbulence model was employed in this paper. Results obtained by experiment are compared with those from the mathematical model. It is found that the results of measurement and simulation agree with each other.
Because of the practical importance of two-phase instabilities, substantial efforts have been made to date to understand the physical phenomena governing such instabilities and to develop computational tools to model ...
详细信息
Because of the practical importance of two-phase instabilities, substantial efforts have been made to date to understand the physical phenomena governing such instabilities and to develop computational tools to model the dynamics. The purpose of this study is to present a numerical model for the analysis of flow-induced instabilities in forced-convection steam generator. The model is based on the assumption of homogeneous two-phase flow and ther- modynamic equilibrium of the phases. The thermal capacity of the heater wall has been included in the analysis. The model is used to analyze the flow instabilities in the steam generator and to study the effects of system pressure, mass flux, inlet temperature and inlet/outlet restriction, gap size, the ratio of do / di, and the ratio of qi / qo on the system be- havior.
Prediction of critical heat flux(CHF)in annular flow is important for the safety of once-through steam generator and the reactor core under accident *** dryout in annular flow occurs at the point where the film is dep...
详细信息
Prediction of critical heat flux(CHF)in annular flow is important for the safety of once-through steam generator and the reactor core under accident *** dryout in annular flow occurs at the point where the film is depleted due to entrainment,deposition,and *** film thickness,film mass flow rate along axial distribution,and CHF are calculated in vertical upward round tube on the basis of a separated flow model of annular *** theoretical CHF values are higher than those derived from experimental data,with error being within 30%.
The vapor-liquid self-adjusting controller is an innovative automatic regulating *** order to ensure adjusted objects run safely and economically,the controller automatically adjusts the liquid flux to keep liquid lev...
详细信息
The vapor-liquid self-adjusting controller is an innovative automatic regulating *** order to ensure adjusted objects run safely and economically,the controller automatically adjusts the liquid flux to keep liquid level at a required level according to physical properties of vapor-liquid two-phase *** adjusting mechanics,the controller’s performance and influencing factors of its stability have been analyzed in this *** theoretical analysis and successful applications have demonstrated this controller can keep the liquid level steady with good *** actual application in industry has shown that the controller can satisfactorily meet the requirement of industrial production and has wide application areas.
The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed...
详细信息
The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed by conductivity probes to determine the liquid slug length distribution. The data covered both the slug and plug flow regimes. From experimental results, the mean liquid slug lengths were relatively insensitive to gas and liquid flow rates in the higher mixture velocity range. But in the lower mixture velocity range, the mean liquid slug length decreased and then increased with mixture velocity. It shows that the development length of slug flow was longer than x/D=1157. A slug tracking model was adapted to study the evolution of liquid slug length distribution in a horizontal pipeline. In the present model, the wake effect of elongated bubble and the pressure drop due to accel-eration are taken into account and random slug lengths are introduced at the entrance. The results of the model are compared with the measured slug length distributions of slug flow regime. It shows that the predicted mean and maximum slug lengths are in agreement with the experimental data at x/D=1157 and the form of the slug length distributions is also predicted well by the model.
暂无评论