The traditional power flow methods aren't appropriate to the electrical distribution systems with distributed generators (DG). Therefore, a direct unbalanced three-phase power flow algorithm was presented in this ...
详细信息
The very fast transient overvoltages(VFTO) are generated during operation of disconnect switch (DS) of gas insulated switchgear(GIS). After the opening operation of DS,the load side busbar is left at a residual *** re...
详细信息
The very fast transient overvoltages(VFTO) are generated during operation of disconnect switch (DS) of gas insulated switchgear(GIS). After the opening operation of DS,the load side busbar is left at a residual *** residual voltage is determined by the opening phase and the breakdown characteristics of SF6 gap of DS. This study obtains the breakdown characteristic of the test DS,including the dielectric strength recovery speed and polarity effect factor of gap of testing *** the stochastic property of DS opening phase,the opening process of DS is simulated by computer under different dielectric strength recovery speeds and polarity effect *** results show that the dielectric strength recovery speed and polarity effect factor have big influences over the residual *** proper value of dielectric strength recovery speed and polarity effect factor could make the residual voltage minor
Neither electromechanical transient stability analysis (TSA) program nor electromagnetic transient (EMT) programs can be used individually for the transient stability studies of the large scale AC/DC systems. This pap...
详细信息
A fast electric field integral in time domain using the uneven discretization and the implicit scheme is proposed to calculate the switching electromagnetic transient at a substation. The switching transient currents ...
详细信息
A fast electric field integral in time domain using the uneven discretization and the implicit scheme is proposed to calculate the switching electromagnetic transient at a substation. The switching transient currents and the resultant radiated electromagnetic field are calculated. The propose d approach has the strength to model the bus system at a substation with a more complicated and realistic configuration that is difficult to simulate using the circuit-based method, because all the electromagnetic couplings within the bus system are included globally. The proposed method might be one of good candidates to predicate the EMI level at a substation.
Travelling-wave starting element is an integral part of the ultra high-speed protection. Existing design method depends on engineering experience, low accuracy in travelling-wave signal recognition, easy to trip frequ...
详细信息
power grid and communication network, which depends on each other to provide proper functionality, are becoming more and more coupled together. Failure of a fraction of nodes in communication networks may lead to a fa...
详细信息
Aimed at power system large-scale blackouts, the paper firstly analyzes the existing problems of current protective relaying and emergency control in power grid. A novel system protection based on local information, p...
详细信息
With high speed data sampling technology development, fault generated high-frequency signals can be got, in which fault generated traveling waves reflects fault location, fault type and faulted equipment so on from di...
详细信息
Recently, several power grids of China came across low frequency oscillations which are difficult to explain by the traditional negative damping mechanism. Some researchers suggest that those oscillations be caused by...
详细信息
Recently, several power grids of China came across low frequency oscillations which are difficult to explain by the traditional negative damping mechanism. Some researchers suggest that those oscillations be caused by external periodic disturbances according to the forced oscillation mechanism. It takes no doubt that the oscillation source location (means locating the disturbances) is imperative and decisive to eliminate such a kind of oscillations. This paper proposes a location methodology based on Energy Supply on Port derived from the Port-controlled Hamiltonian theory. By calculating the energy injected to the network at corresponding ports, the oscillation sources can be effectively located, even in complicated systems containing various kinds of control devices such as governors and exciters. Different from the traditional methodology based on eigen-analysis, the proposed methodology is naturally decentralized without the dependency on global measurements. Case studies on the standard 4-machine 2-area system and the IEEE-118 bus system show the effectiveness and efficiency of the proposed methodology.
Distribution line non-communication protection (DNCP) can quickly and selectively isolate unsymmetrical fault, but the performance of this distribution line automation system is not satisfying in the case of symmetric...