This paper, the mechanism of valve electric actuator failures is analyzed, and the fault diagnosis method based on principle component analysis (PCA) and support vector machines (SVM) is put forward. In order to reduc...
详细信息
The article proposed a new method for implementing linear phase FIR filter based on FPGA. For the key to implementing the FIR filter on FPGA-multiply-add operation, a parallel distributed algorithm was presented, whic...
详细信息
The structure and function of Siemens communication protocol chip DPC31 are introduced in this paper, a development scheme of DP smart slave station based on DPC31 is proposed, and the design method for software and h...
详细信息
Focusing on solving the problem that the traditional super-loops can not meet the requirement of Modern controlsystems no matter on resource management and system control, this paper introduces a way to construct an ...
详细信息
The control strategy of grid-connected inverter has always been a core question of generating systems. This paper analyzed three kinds of ways pf inverter's output current based on the current control mode. Those ...
详细信息
ISBN:
(纸本)9781467323635
The control strategy of grid-connected inverter has always been a core question of generating systems. This paper analyzed three kinds of ways pf inverter's output current based on the current control mode. Those are current hysteretic comparison control method, timing control of current instantaneous comparison method and the triangle wave comparison control method of timing tracking current. And all of three were simulated by MATLAB/Simulink. It turned out to be that the three methods for grid-connected inverter have good grid effect. Each of them has their advantages and disadvantages in grid control strategy. All of them will provide theoretical basis for further research.
The main purpose of the Joint Detection (JD) techniques is an accurately estimating the user's signal, the difficulty lies in the system matrix inversion, so to find the fast inversion algorithms is the main key t...
详细信息
Profibus-DP fieldbus has been the research focus in the field of industrial automation and control, and there're kinds of relevant *** slave station, one of the products used in connecting the master station and t...
详细信息
Profibus-DP fieldbus has been the research focus in the field of industrial automation and control, and there're kinds of relevant *** slave station, one of the products used in connecting the master station and the industrial units like frequency converter, sensor and meter and so on, is the key technology now researched.A design of Profibus-DP slave station based on DPRAM is proposed in this ***, a overall design of hardware for the slave station is ***, the design for the core module of the slave station and the user interface are mainly *** the end, the design of the software for the slave station is proposed, and the connection between the industrial units and the Profibus-DP master station is realized.
In this paper, the feasibility of co-channel coexistence of Time Division- Synchronous Code Division Multiple Access (TD-SCDMA) and Code Division Multiple Access 2000 (CDMA2000) systems operating in a macro cell envir...
详细信息
The boiler's drum water level is a material balance indicator between which are the output of steam and water supply. It is a parameter of both the security and the quality. Some questions in the existing automati...
详细信息
According to the problem of the large calculated quantity and unavailable of multiple sources tracking in real time in the traditional DOA estimation algorithm which is disabled when locating sources that are greater ...
详细信息
暂无评论