A fast electric field integral in time domain using the uneven discretization and the implicit scheme is proposed to calculate the switching electromagnetic transient at a substation. The switching transient currents ...
详细信息
The large-size planar DC bus bar is widely used in high power converters, whose stray parameters are significantly affected the converter reliability and performance. Taking the example of an actual 315kW/400V inverte...
详细信息
The large-size planar DC bus bar is widely used in high power converters, whose stray parameters are significantly affected the converter reliability and performance. Taking the example of an actual 315kW/400V inverter, the design, simulation and analysis for its bus bar stray parameters is described in detailed. Being different from the conventional method that considers the bus bar conductor as an entirety, an improved method is proposed in this paper, which separates the bus bar into several segments and evaluates the influence of stray parameters in each segment to the power semiconductor devices respectively. Therefore, this improved method can provide support for the more accurate and effective design and optimization of bus bar. In addition, two different structure of bus bar are implemented in the actual inverter, the comparison and analysis of experiment results for both structures proves the validity of the proposed method.
Formulation of day-ahead operation schedule for large-scale power grid requires security validation, including static security, dynamic and transient stability. It is an important and basic task for day-ahead security...
详细信息
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durat...
详细信息
ISBN:
(纸本)9781849196208
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durations are controlled by the tripping time of overcurrent relay in power collection lines based on the sags' magnitude. The specification of the LVRT capacity of wind generator is introduced into the operation characteristics of the relay in power collection lines. The evaluation model of equivalent LVRT capacity to overcurrent protection is proposed in paper, and the equivalent LVRT capacities from zone I and zone II relay are quantified. Improvement measures are also proposed.
To increase efficiency is an essential target in photovoltaic (PV) powergeneration system. The losses of the whole system consist of several parts. This paper focuses on the losses of the hard-switching devices. An i...
详细信息
ISBN:
(纸本)9781467323277
To increase efficiency is an essential target in photovoltaic (PV) powergeneration system. The losses of the whole system consist of several parts. This paper focuses on the losses of the hard-switching devices. An improved method to calculate the device losses is proposed. And influences of different factors like DC link voltage, input power, switching frequency and power factor on the losses are considered. Then this paper compares the losses of conventional two-level inverter and of diode-clamped three-level inverter to provide the evaluation of power losses under different working conditions. This is helpful to design and optimize a certain PV inverter. Calculating results based on an actual three phase 10kW PV inverter are presented.
power transformer condition assessment is the basi of condition-based maintenance and plays a very important role in carrying assets management and risk assessment for power system. As the heart of transmission and tr...
详细信息
power transformer condition assessment is the basi of condition-based maintenance and plays a very important role in carrying assets management and risk assessment for power system. As the heart of transmission and transformation system, power transformer's condition has close relation with many factors, such as the production quality of itself, operation environment and so on. This paper analyzes some variables which could represent the transformer's condition, including the data from preventative test, factory test and commission test, diagnostic test, on-line detection and monitoring, routine inspection, operation history, family defection and environment information. Some parameters which have representation are chosen as the condition variables. Artificial neuron network (ANN) and Dempster-Shafer (D-S) evidence theory are adopted to form the multiparameter information fusion condition assessment model. Besides the static value, the change trends of some parameters are considered as an independent evidence section. Cooperating with on-line monitoring, it will be helpful to improve the accuracy and efficiency of condition assessment.
By taking into account the real-time measurement with low redundancy and of only partial current in distribution systems and referring to the quasi-real-time current measuring data of the metering system, the current ...
详细信息
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durat...
详细信息
ISBN:
(纸本)9781622761050
Magnitude and duration of voltage sags are the most important two factors to the Lower Voltage Ride Through (LVRT) capacity of the wind generator. Since most voltage sags are caused by the system faults, and sag durations are controlled by the tripping time of overcurrent relay in power collection lines based on the sags' magnitude. The specification of the LVRT capacity of wind generator is introduced into the operation characteristics of the relay in power collection lines. The evaluation model of equivalent LVRT capacity to overcurrent protection is proposed in paper, and the equivalent LVRT capacities from zone I and zone II relay are quantified. Improvement measures are also proposed.
A substation three-phase nonlinear state estimation method based on zero impedance branches helps to identify topology and analogy errors at substation level and accordingly enhances the control center's state est...
详细信息
A substation three-phase nonlinear state estimation method based on zero impedance branches helps to identify topology and analogy errors at substation level and accordingly enhances the control center's state estimation reliability and accuracy. Some issues during the practical implementation process of the technology are reported, such as the hardware configuration, measurement integration, the communication between substation and control center, time setting and period selection. The benefits of the proposed technology have also been analyzed. It is shown that this technology has high reliability and low burden on communication, and improves the ability of monitoring of power grids and the reliability of the real-time power network model significantly. The proposed technology is verified effective by both simulation experiments and field-site applications in East China power Grid, and is well qualified for real-time online applications, which has broad popularization and application prospects.
A substation topology error identification method based on comprehensive rules, including rules in different spatial scales such as element level, bay level and voltage level as well as rules in time sequence, is pres...
详细信息
A substation topology error identification method based on comprehensive rules, including rules in different spatial scales such as element level, bay level and voltage level as well as rules in time sequence, is presented. Utilizing the superiority in multi-source, redundancy and rapid measurement in the substation, the multi spatial scale relevant rules of element, bay and voltage level as well as multi time sequence rules are proposed, and concrete implementation approach for such a method is given. The proposed method can improve the ability to identify the topology error, especially ability to identify switches without analog measurement, thus more reliable topological structure can be provided to control centre to improve the reliability of state estimation for the whole power system. Results of simulation and practical application show that the proposed method is effective.