Under the skin effect caused by the alternating electromagnetic field, the transmission line parameters changes with frequency, and different line resistivity, surge impedance, wave speed are presented in one line und...
详细信息
With high speed data sampling technology development, fault generated high-frequency signals can be got, in which fault generated traveling waves reflects fault location, fault type and faulted equipment so on from di...
详细信息
Traditional operation rules depend on human experience, which are relatively fixed and difficult to fulfill the new demand of the modern power grid. In order to formulate suitable and quickly refreshed operation rules...
详细信息
Traditional operation rules depend on human experience, which are relatively fixed and difficult to fulfill the new demand of the modern power grid. In order to formulate suitable and quickly refreshed operation rules, a method of linear decision tree based on support samples is proposed for rule extraction in this paper. The operation rules extracted by this method have advantages of refinement and intelligence, which helps the dispatching center meet the requirement of smart grid construction.
Wind power outputs fluctuate with the changing of wind speed. The use of energy storage equipment is considered a reasonable solution to suppress wind power fluctuations. An energy storage mode may have its disadvanta...
详细信息
Wind power outputs fluctuate with the changing of wind speed. The use of energy storage equipment is considered a reasonable solution to suppress wind power fluctuations. An energy storage mode may have its disadvantages over the others, for example, capacity limits, dynamic response, higher prices or shorter lifetime. Moreover, wind power fluctuations are present at different frequencies, to demand the energy storage to offer power support in different time ranges. To improve the performance, in this paper, a combined energy storage mode is discussed to meet the short-term and longterm energy storage requirement for wind power. Short-term energy storage is designed to meet the fast-changing power, using such as super capacitors. Long-term energy is designed to meet the large-scale capacity requirement using Li-ion battery or Vanadium Redox Battery(VRB). By analyzing the actual data of wind power outputs, the capacities of the two kinds of energy storage means are given as an example of the method.
Wind power outputs fluctuate with the changing of wind speed. The use of energy storage equipment is considered a reasonable solution to suppress wind power fluctuations. An energy storage mode may have its disadvanta...
详细信息
Wind power outputs fluctuate with the changing of wind speed. The use of energy storage equipment is considered a reasonable solution to suppress wind power fluctuations. An energy storage mode may have its disadvantages over the others, for example, capacity limits, dynamic response, higher prices or shorter lifetime. Moreover, wind power fluctuations are present at different frequencies, to demand the energy storage to offer power support in different time ranges. To improve the performance, in this paper, a combined energy storage mode is discussed to meet the shortterm and long-term energy storage requirement for wind power. Short-term energy storage is designed to meet the fast-changing power, using such as super capacitors. Long-term energy is designed to meet the large-scale capacity requirement using Li-ion battery or Vanadium Redox Battery(VRB). By analyzing the actual data of wind power outputs, the capacities of the two kinds of energy storage means are given as an example of the method.
Distribution line non-communication protection (DNCP) can quickly and selectively isolate unsymmetrical fault, but the performance of this distribution line automation system is not satisfying in the case of symmetric...
详细信息
A substation three-phase nonlinear state estimation method based on zero impedance branches is presented in order to eliminate topology and analogy errors at substation level and accordingly enhance the control center...
详细信息
Standardization is the development tendency of information exchange among control centers. Based on the standard in IEC 61970, an information exchange model suitable for coordinated automatic voltage control (CAVC) am...
详细信息
Standardization is the development tendency of information exchange among control centers. Based on the standard in IEC 61970, an information exchange model suitable for coordinated automatic voltage control (CAVC) among multi control centers is proposed. Firstly, the contents of information flow of CAVC is analyzed and the definition of coordinated control model for information exchange is given;then the common information model is extended and a standardized information model for CAVC is designed;and then based on component interface specification, a standardized information exchange interface for CAVC is designed and its architecture for information exchange as well as its information exchange procedure are given. The presented information exchange model possesses wide application prospect in the implementation of information exchange among multi CAVC control centers for future smart grids.
With the development of plug-in hybrid electric vehicles (PHEVs), power electronics plays an increasingly important role in electric power train systems. The economic and reliable design of these power electronic syst...
详细信息
Lightning is a major cause of power interruptions in power transmission lines. Nowadays the Leader Progression Model is an advanced method to evaluate the shielding failure probability of transmission lines. Calculati...
详细信息