With widely utilization of distributed generations (DGs) and demand response (DR), the active distribution network (ADN) becomes a more proactive and strategic consumer in electricity markets to procure its energy nee...
详细信息
To protect the environment and lower carbon dioxide emissions, conventional fossil-fuel generators tend to be replaced by renewable generation. The volatile and uncertain renewable generation, as well as the reduced p...
详细信息
Commutation failure (CF) is one of the major concerns in high-voltage direct current (HVDC) transmission system. Of many methods to mitigate CF, advancing firing angle is preferred one since it can be easily implement...
详细信息
IPS has many special characteristics, such as using multi-phase, multi-frequency and hybrid AC/DC devices. As a result, existing electromagnetic transient simulators developed for powersystems on land do not apply to...
详细信息
The thermal inertia induced by heat accumulation in hundreds of tons of refractory castables during variable loads critically limits the operational flexibility of circulating fluidized bed (CFB) boilers, yet existing...
详细信息
Multi-energy systems may contain integrated energy networks such as electrical, gas and heating networks. The differences in the physical characteristics of each energy network make it difficult to solve power flows o...
详细信息
Fault location in distribution systems includes 2 subtasks: fault distance estimation and fault section identification. This paper presents a fault location method based on reclosure-generating traveling waves and sys...
详细信息
Dielectric barrier discharge (DBD) between two cylindrical glass containers with salt water generated by a nanosecond repetitively pulsed power generator is reported. The electrical parameters, luminous images and s...
详细信息
Dielectric barrier discharge (DBD) between two cylindrical glass containers with salt water generated by a nanosecond repetitively pulsed power generator is reported. The electrical parameters, luminous images and spectrum diagnosis are presented. It is shown that the DBD possesses a large discharge current and an intense optical emission from the nitrogen second positive system below 400 nm. The gas temperature remains very close to room temperature regardless of pulse polarity. Luminous photographs with a short exposure time down to 2 ns indicate that no filament is observed and the discharge is homogeneous.
Five-level active neutral-point-clamped (ANPC) converter is a newly emerging topology which can overcome the drawbacks of traditional neutral-point-clamped and flying-capacitor multilevel converters. During the start-...
详细信息
Travelling wave (TW) differential protection fully utilizes the fault information contained in TW at both terminals of a transmission line, so it's a protection with high reliability and high selectivity. However,...
详细信息
ISBN:
(纸本)9781785618260
Travelling wave (TW) differential protection fully utilizes the fault information contained in TW at both terminals of a transmission line, so it's a protection with high reliability and high selectivity. However, because TW differential protection needs a large amount of communication, it cannot be put into practical use. This paper proposes a TW differential protection which is based on equivalent travelling wave (ETW). Fault information is not lost during the process of getting ETW, so the proposed protection has the same reliability and selectivity with traditional TW differential protection. Because only several modulus maxima are needed to be sent to the opposite terminal, the traffic is largely reduced and the protection can operate much more rapidly. Extensive simulations validate the proposed protection.
暂无评论